A fast method for the determination of As, Co, Cu, Fe, Mn, Ni, Se and V in biological samples by ETV-ICP-MS, after a simple sample treatment with formic acid, is proposed. Approximately 75 mg of each sample is mixed with 5 mL of formic acid, kept at 90°C for 1 h and then diluted with nitric acid aqueous solution to a 5% (v/v) formic acid and 1% (v/v) nitric acid final concentrations. A palladium solution was used as a chemical modifier. The instrumental conditions, such as carrier gas flow rate, RF power, pyrolysis and vaporization temperatures and argon internal flow rate during vaporization were optimized. The formic acid causes a slight decrease of the analytes signal intensities, but does not increase the signal of the mainly polyatomic ions ((14)N(35)Cl(+), (14)N(12)C(+), (40)Ar(12)C(+), (13)C(37)Cl(+), (40)Ar(36)Ar(+), (40)Ar(35)Cl(+), (35)Cl(16)O(+), (40)Ar(18)O(+)) that affect the analytes signals. The effect of charge transfer reactions, that could increase the ionization efficiency of some elements with high ionization potentials was not observed due to the elimination of most of the organic compounds during the pyrolysis step. External calibration with aqueous standard solutions containing 5% (v/v) formic acid allows the simultaneous determination of all analytes with high accuracy. The detection limits in the samples were between 0.01 (Co) and 850 μg kg(-1) (Fe and Se) and the precision expressed by the relative standard deviations (RSD) were between 0.1% (Mn) and 10% (Ni). Accuracy was validated by the analysis of four certified reference biological materials of animal tissues (lobster hepatopancreas, dogfish muscle, oyster tissue and bovine liver). The recommended procedure avoids plasma instability, carbon deposit on the cones and does not require sample digestion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2011.12.030DOI Listing

Publication Analysis

Top Keywords

formic acid
24
biological samples
8
acid
8
nitric acid
8
v/v formic
8
flow rate
8
formic
6
electrothermal vaporizer
4
vaporizer coupled
4
coupled inductively
4

Similar Publications

Development and validation of an LC-MS/MS method for quantifying total and unbound doravirine in human plasma.

J Chromatogr B Analyt Technol Biomed Life Sci

December 2024

Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, Cape Town, South Africa. Electronic address:

A robust LC-MS/MS method was developed to quantify total and unbound doravirine in plasma samples from patients receiving daily doses of 100 mg doravirine, in combination with lamivudine and tenofovir disoproxil fumarate, in a phase 3 clinical trial. The trial is ongoing, and sample analysis is planned to commence once all samples have been collected. The method was validated to quantify both total and unbound doravirine using a single calibration curve.

View Article and Find Full Text PDF

Development and optimization of a high-throughput HPLC-MS/MS method for the simultaneous determination of Cedazuridine, Gemcitabine and its metabolite in mouse plasma.

J Chromatogr B Analyt Technol Biomed Life Sci

December 2024

Department of Pharmaceutical Analysis, Wuya College of Innovation, Shenyang Pharmaceutical University, No. 103, Wenhua Road, Shenyang 110016, China. Electronic address:

Gemcitabine (GEM) has been extensively applied in treating various solid tumors. Nonetheless, GEM is easily metabolized in vivo by cytidine deaminase (CDA) to inactive 2', 2'-Difluorodeoxyuridine (dFdU) results in a low oral bioavailability, which limit its clinical application. It was found that Cedazuridine (CDZ) could effectively inhibit the deamination of the drug by CDA, and its combination with GEM might affect the oral bioavailability of GEM.

View Article and Find Full Text PDF

Background: Tavaborole (TAV), a benzoxaborole derivative, is an FDA-approved antifungal agent for treating onychomycosis, a common and persistent fungal infection of the toenails.

Objective: This study aimed to develop a robust stability-indicating HPTLC method to determine TAV in nanostructured lipid carriers (NLC) using a comprehensive approach that includes risk assessment, and Analytical Quality by Design.

Methods: The critical method parameters influencing the HPTLC results were screened using a Placket-Burman screening design followed by its optimization using a central composite optimization design.

View Article and Find Full Text PDF

Background: Microglia play significant roles in Alzheimer's disease (AD) pathophysiology. Current evidence suggests microglia may function in both protective and degenerative capacities, which has received little clarity from transcriptionally-characterised phenotypes uncovered from transgenic pathologies alone. BIN1 - the second-most significant risk gene for the development of late-onset AD (LOAD) - is expressed at high levels in neurons, oligodendrocytes and microglia.

View Article and Find Full Text PDF

A Simple and Sensitive LC-MS/MS Method for the Determination of Mobocertinib and Its Metabolite Desmethyl-Mobocertinib in Human Plasma and Its Application to Clinical Pharmacokinetic Study.

Biomed Chromatogr

February 2025

Yangzhou University Medical College, Jiangsu Key Laboratory of Experimental & Translational Non-coding RNA Research, Institute of Translational Medicine, Yangzhou University, Yangzhou, Jiangsu Province, China.

Mobocertinib is a potent selective tyrosine kinase inhibitor approved for the treatment of non-small cell lung cancer with activating EGFR exon 20 insertions. The aim of this study was to develop a procedure for liquid chromatography tandem mass spectrometry (LC-MS/MS) for the determination of mobocertinib and its metabolite desmethyl-mobocertinib in human plasma. The human plasma samples were precipitated with acetonitrile and analyzed using a Waters ACQUITY BEH C column coupled to a triple quadrupole mass spectrometer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!