A major problem that often arises in modeling Micro Electro Mechanical Systems (MEMS) such as Surface Acoustic Wave (SAW) sensors using Finite Element Analysis (FEA) is the extensive computational capacity required. In this study a new approach is adopted to significantly reduce the computational capacity needed for analyzing the response of a SAW sensor using the finite element (FE) method. The approach is based on the plane wave solution where the properties of the wave vary in two dimensions and are uniform along the thickness of the device. The plane wave solution therefore allows the thickness of the SAW device model to be minimized; the model is referred to as a Reduced 3D Model (R3D). Various configurations of this novel R3D model are developed and compared with theoretical and experimental frequency data and the results show very good agreement. In addition, two-dimensional (2D) models with similar configurations to the R3D are developed for comparison since the 2D approach is widely adopted in the literature as a computationally inexpensive approach to model SAW sensors using the FE method. Results illustrate that the R3D model is capable of capturing the SAW response more accurately than the 2D model; this is demonstrated by comparison of centre frequency and insertion loss values. These results are very encouraging and indicate that the R3D model is capable of capturing the MEMS-based SAW sensor response without being computationally expensive.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3267204 | PMC |
http://dx.doi.org/10.3390/s91209945 | DOI Listing |
Sci Rep
January 2025
Science and Technology on Vacuum and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou, 730000, China.
The Laser Interferometer Space Antenna (LISA) mission is designed to detect space gravitational wave sources in the millihertz band. A critical factor in the success of this mission is the residual acceleration noise metric of the internal test mass (TM) within the ultra-precise inertial sensors. Existing studies indicate that the coupling effects of residual gas and temperature gradient fluctuations significantly influence this metric, primarily manifesting as the radiometer effect and the outgassing effect.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Orthopaedic Surgery, School of Medicine, International University of Health and Welfare, 4-3, Kozunomori, Narita, Chiba, 286-8686, Japan.
The occurrence of diseases characterized by irregular spinal alignment, such as kyphosis, lordosis, scoliosis, and dropped head syndrome (DHS) is increasing, particularly among older adults. DHS is characterized by an excessive forward tilt of the head and neck, causing the head to droop. Although it is believed that muscle activity plays a role in both the onset and treatment of DHS, the underlying mechanisms remain unclear.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Electrical and Electronic Engineering, Pabna University of Science and Technology, Pabna, Bangladesh.
Waterborne bacteria pose a serious hazard to human health, hence a precise detection method is required to identify them. A photonic crystal fiber sensor that takes into account the dangers of aquatic bacteria has been suggested, and its optical characteristics in the THz range have been quantitatively assessed. The PCF sensor was designed and examined as computed in Comsol Multiphysics, a program in which uses the method of "Finite Element Method" (FEM).
View Article and Find Full Text PDFActa Bioeng Biomech
September 2024
Xinjiang University, China.
: The purpose of this study was to investigate dynamic responses of Lenke1B+ spines of adolescent scoliosis patients to different frequencies. : Modal analysis, harmonic response analysis and transient dynamics of a full spine model inverted by the finite element method using Abaqus. : The first-order axial resonance frequency of 4.
View Article and Find Full Text PDFActa Bioeng Biomech
September 2024
Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education.
: Elbow contracture is a common complication post-elbow trauma, the biomechanical environment after anterior capsule injury was complex. This study aimed to use a finite element model to investigate the biomechanical environment within elbow capsule and its surrounding tissues at various stages after anterior capsule injury. : A finite element model of the elbow joint, incorporating muscle activation behavior, was developed to simulate elbow flexion under normal condition (no injury) and at 2, 4, 6 and 8 weeks following anterior joint capsular injury.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!