To measure the scapulohumeral rhythm (SHR) in outpatient settings, the motion analysis protocol named ISEO (INAIL Shoulder and Elbow Outpatient protocol) was developed, based on inertial and magnetic sensors. To complete the sensor-to-segment calibration, ISEO requires the involvement of an operator for sensor placement and for positioning the patient's arm in a predefined posture. Since this can affect the measure, this study aimed at quantifying ISEO intra- and inter-operator agreement. Forty subjects were considered, together with two operators, A and B. Three measurement sessions were completed for each subject: two by A and one by B. In each session, the humerus and scapula rotations were measured during sagittal and scapular plane elevation movements. ISEO intra- and inter-operator agreement were assessed by computing, between sessions, the: (1) similarity of the scapulohumeral patterns through the Coefficient of Multiple Correlation (CMC(2)), both considering and excluding the difference of the initial value of the scapula rotations between two sessions (inter-session offset); (2) 95% Smallest Detectable Difference (SDD(95)) in scapula range of motion. Results for CMC(2) showed that the intra- and inter-operator agreement is acceptable (median≥0.85, lower-whisker ≥ 0.75) for most of the scapula rotations, independently from the movement and the inter-session offset. The only exception is the agreement for scapula protraction-retraction and for scapula medio-lateral rotation during abduction (inter-operator), which is acceptable only if the inter-session offset is removed. SDD(95) values ranged from 4.4° to 8.6° for the inter-operator and between 4.9° and 8.5° for the intra-operator agreement. In conclusion, ISEO presents a high intra- and inter-operator agreement, particularly with the scapula inter-session offset removed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gaitpost.2011.12.015DOI Listing

Publication Analysis

Top Keywords

intra- inter-operator
20
inter-operator agreement
20
inter-session offset
16
scapula rotations
12
scapulohumeral rhythm
8
based inertial
8
inertial magnetic
8
magnetic sensors
8
iseo intra-
8
agreement scapula
8

Similar Publications

Axillary lymph node (ALN) staging is crucial for the management of invasive breast cancer (BC). Although various radiological investigations are available, ultrasound (US) is the preferred tool for evaluating ALNs. Despite its immediacy, widespread use, and good predictive value, US is limited by intra- and inter-operator variability.

View Article and Find Full Text PDF

Comparison of Different 3D Surface Registration-Based Methods to Assess Facial Asymmetry.

Diagnostics (Basel)

November 2024

LAFAS (Laboratory of Functional Anatomy of the Stomatognathic System), Department of Biomedical Sciences for Health, University of Milan, 20133 Milan, Italy.

Background/objectives: Facial asymmetry is gaining an increasing diagnostic interest in many clinical contexts. Several three-dimensional surface-based methods have been proposed for its assessment; however, they might provide non-equivalent data. Since there is a lack of comparative studies in these terms, this study aims to compare three methods for assessing the asymmetry of the face and facial thirds, thus addressing whether the potential differences can be considered clinically acceptable or not.

View Article and Find Full Text PDF

Purpose: Sentinel lymph node biopsy (SLNB) has been recognized as "the gold standard" for axillary staging in early breast cancer patients with clinically negative lymph nodes, resulting in significant morbidity decrease and quality of life improvement. This study aims to validate the performance of a newly developed handheld portable gamma camera (PGC) produced by Imagensys (Italy), in detecting and locating sentinel lymph nodes (SLNs) during the preoperative and intraoperative phases in breast cancer patients compared to conventional lymphoscintigraphy.

Methods: Adult female patients with histologically confirmed breast cancer, candidates for surgery and SLNB, were prospectively enrolled in this open-label, pre-marketing clinical trial.

View Article and Find Full Text PDF

Purpose: Transaxial CT imaging is the main clinical imaging modality for the assessment of COVID-induced lung damage. However, this type of data does not quantify the functional properties of the lung. The objective is to provide non-invasive personalized cartographies of lung stiffness for long-COVID patients using MR elastography (MRE) and follow-up the evolution of this quantitative mapping over time.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to establish normal reference ranges for the fetal right ventricular modified myocardial performance index (RV Mod-MPI) using an automated system to measure heart function in normal and congenital diaphragmatic hernia (CDH) fetuses.
  • It found that the automated measurements showed significantly better reproducibility compared to manual methods, with a high intraclass correlation coefficient (ICC).
  • Additionally, the study revealed that RV Mod-MPI values increased with gestational age, but there was no significant difference between fetuses with CDH and normal fetuses.
View Article and Find Full Text PDF