A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Determination of trace nickel in bi-based superconductor powder by inductively coupled plasma atomic emission spectroscopy after separation with anion exchange resin and extraction with methylbenzene]. | LitMetric

A new method for the determination of trace nickel in superconductor powder by ICP-AES was proposed. The instrument parameters were optimized, and the matrix effects as well as the method of eliminating interferences were also studied systemically. The results showed that matrix interference in the superconductor powder was serious when the amount of matrix increased, and the repeatability as well as the accuracy was poor, so it was necessary to used separation and preconcentration to improve the accuracy and precision. In this experiment, Ni-diacetyl dioxime complexes were enriched by toluene extraction in alkaline condition after eliminating the interference of major element Bi and partial Pb, Sr, Ca and Cu by eluting with anion exchange resin, then the Ni-complexes were back extracted by diluted hydrochloric acid. The enrichment conditions were investigated in detail and the recovery rate of Ni was higher than 95%. Under the optimal condition, an artificial sample was analysed, the result showed that the found values were identical with reference values, and the RSD and detection limit were 1.9% and 0.19 microg x g(-1), respectively. The method has been applied to the determination of trace nickel in Bi-based superconductor powder samples with satisfactory results.

Download full-text PDF

Source

Publication Analysis

Top Keywords

superconductor powder
16
trace nickel
12
nickel bi-based
8
bi-based superconductor
8
anion exchange
8
exchange resin
8
determination trace
8
[determination trace
4
superconductor
4
powder
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!