This prospective study evaluated the accuracy of grey-scale two-dimensional (2D) ultrasonography and real-time threedimensional (3D) ultrasonography-based virtual cystoscopy for detecting early recurrence of bladder cancer in previously treated patients (n = 40). Real-time 3D ultrasonography-based virtual cystoscopy images were compared with both 2D ultrasonography and interval conventional cystoscopy pathology results. Ultrasound examinations were performed before routine follow-up with conventional cystoscopy. Overall sensitivity for real-time 3D ultrasonography-based virtual cystoscopy was lower than for 2D ultrasonography, indicating it did not provide additional information. The results of combined (2D and 3D) ultrasonography and conventional cystoscopy differed significantly. Where lesions were detected with combined ultrasonography, the number of previous cystoscopies was lower and the tumour stage was significantly higher at initial diagnosis, compared with cases where no lesions were detected. The results suggest that ultrasonography before cystoscopy can be performed more frequently - or, if no lesions are detected by ultrasonography, the interval between cystoscopies can be prolonged - in patients at high risk of bladder cancer recurrence.

Download full-text PDF

Source
http://dx.doi.org/10.1177/147323001103900623DOI Listing

Publication Analysis

Top Keywords

ultrasonography-based virtual
16
virtual cystoscopy
16
bladder cancer
12
conventional cystoscopy
12
lesions detected
12
cancer recurrence
8
cystoscopy
8
real-time ultrasonography-based
8
ultrasonography interval
8
combined ultrasonography
8

Similar Publications

This prospective study evaluated the accuracy of grey-scale two-dimensional (2D) ultrasonography and real-time threedimensional (3D) ultrasonography-based virtual cystoscopy for detecting early recurrence of bladder cancer in previously treated patients (n = 40). Real-time 3D ultrasonography-based virtual cystoscopy images were compared with both 2D ultrasonography and interval conventional cystoscopy pathology results. Ultrasound examinations were performed before routine follow-up with conventional cystoscopy.

View Article and Find Full Text PDF

Objective: The purpose of this study was to validate the feasibility and potential of 3-dimensional ultrasonography (3DUS)-based virtual cystoscopy in the pediatric urinary bladder.

Methods: Twenty patients (age range, newborn-14 years) underwent urinary tract ultrasonography and 3DUS of the urinary bladder. From this data set, virtual cystoscopy was reconstructed for visualization of the inner bladder surface.

View Article and Find Full Text PDF

Object: The relatively stationary anatomy of the intracranial compartment has allowed the development of stereotactic radiosurgery as an effective treatment option for many intracranial lesions. Difficulty in accurately tracking extracranial targets has limited its development in the treatment of these lesions. The ability to track extracranial structures in real time with ultrasound images allows a system to upgrade and interface pretreatment volumetric images for extracranial applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!