This prospective study evaluated the accuracy of grey-scale two-dimensional (2D) ultrasonography and real-time threedimensional (3D) ultrasonography-based virtual cystoscopy for detecting early recurrence of bladder cancer in previously treated patients (n = 40). Real-time 3D ultrasonography-based virtual cystoscopy images were compared with both 2D ultrasonography and interval conventional cystoscopy pathology results. Ultrasound examinations were performed before routine follow-up with conventional cystoscopy. Overall sensitivity for real-time 3D ultrasonography-based virtual cystoscopy was lower than for 2D ultrasonography, indicating it did not provide additional information. The results of combined (2D and 3D) ultrasonography and conventional cystoscopy differed significantly. Where lesions were detected with combined ultrasonography, the number of previous cystoscopies was lower and the tumour stage was significantly higher at initial diagnosis, compared with cases where no lesions were detected. The results suggest that ultrasonography before cystoscopy can be performed more frequently - or, if no lesions are detected by ultrasonography, the interval between cystoscopies can be prolonged - in patients at high risk of bladder cancer recurrence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/147323001103900623 | DOI Listing |
J Int Med Res
May 2012
Department of Radiology, Cerrahpasa Faculty of Medicine, Istanbul University, Istanbul, Turkey.
This prospective study evaluated the accuracy of grey-scale two-dimensional (2D) ultrasonography and real-time threedimensional (3D) ultrasonography-based virtual cystoscopy for detecting early recurrence of bladder cancer in previously treated patients (n = 40). Real-time 3D ultrasonography-based virtual cystoscopy images were compared with both 2D ultrasonography and interval conventional cystoscopy pathology results. Ultrasound examinations were performed before routine follow-up with conventional cystoscopy.
View Article and Find Full Text PDFJ Ultrasound Med
October 2008
Department of Radiology, Division of Pediatric Radiology, University Hospital LKH Graz, Auenbruggerplatz, A-8036 Graz, Austria.
Objective: The purpose of this study was to validate the feasibility and potential of 3-dimensional ultrasonography (3DUS)-based virtual cystoscopy in the pediatric urinary bladder.
Methods: Twenty patients (age range, newborn-14 years) underwent urinary tract ultrasonography and 3DUS of the urinary bladder. From this data set, virtual cystoscopy was reconstructed for visualization of the inner bladder surface.
Neurosurg Focus
December 2001
Department of Neurosurgery, University of Iowa, Iowa City, Iowa 52242-1077, USA.
Object: The relatively stationary anatomy of the intracranial compartment has allowed the development of stereotactic radiosurgery as an effective treatment option for many intracranial lesions. Difficulty in accurately tracking extracranial targets has limited its development in the treatment of these lesions. The ability to track extracranial structures in real time with ultrasound images allows a system to upgrade and interface pretreatment volumetric images for extracranial applications.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!