Objectives: Thoracic aortic aneurysm and thoracic aortic dissection are related and potentially deadly diseases that present with nonspecific symptoms. Transthoracic echocardiography (TTE) may detect thoracic aortic pathology and is being increasingly performed by the emergency physician at the bedside; however, the accuracy of point-of-care (POC) focused cardiac ultrasound (FOCUS) for thoracic aortic aneurysm and thoracic aortic dissection has not been studied. The objective of this pilot study was to explore the agreement, sensitivity, and specificity of FOCUS for thoracic aortic dimensions, dilation, and aneurysm compared with CT angiography (CTA) as the reference standard.
Methods: This study was a retrospective pilot analysis of image and chart data on consecutive patients presenting to an urban, academic emergency department (ED) between January 2008 and June 2010, who had both a FOCUS and a CTA for suspicion of thoracic aorta pathology. Thoracic aorta dimensions were measured from recordings by three ultrasound-trained emergency physicians blinded to any initial FOCUS and CTA results. CTA measurements were obtained by a radiologist blinded to the FOCUS results. Using cutoffs of 40 and 45 mm, we calculated the sensitivity and specificity of FOCUS for aortic dilation and aneurysm with the largest measurement on CT as the reference standard. Bland-Altman plots with 95% limits of agreement were used to demonstrate agreement for aortic measurements, kappa statistics to assess the degree of agreement between tests for aortic dilation, and intraclass correlation for interobserver and intraobserver variability.
Results: Ninety-two patients underwent both FOCUS and CTA during the study period. Ten FOCUS studies had inadequate visualization for all measurements areas. Eighty-two patients were included in the final analysis. Mean (±SD) age was 58.1 (±16.6) years and 58.5% were male. Sensitivity, specificity, and the observed kappa value (95% confidence interval [CI]) between FOCUS and CTA for the presence of aortic dilation at the 40-mm cutoff were 0.77 (95% CI = 0.58 to 0.98), 0.95 (95% CI = 0.84 to 0.99), and 0.74 (95% CI = 0.58 to 0.90), respectively. The mean difference (95% limits of agreement) for the Bland-Altman plots was 0.6 mm (-5.3 to 6.5) for the sinuses of Valsalva, 4 mm (-2.7 to 10.7) for the sinotubular junction, 1.5 mm (-5.8 to 8.8) for the ascending aorta, and 2.2 mm (-5.9 to 10.3) for the descending aorta.
Conclusions: In this retrospective pilot study, FOCUS demonstrated good agreement with CTA measurements of maximal thoracic aortic diameter. FOCUS appears to be specific for aortic dilation and aneurysm when compared to CTA, but requires further prospective study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1553-2712.2011.01279.x | DOI Listing |
BMC Cardiovasc Disord
January 2025
Department of Thoracic and Cardiovascular Surgery, Nanjing First Hospital, Nanjing Medical University, Nanjing, China.
Background: The aim of this study was to investigate whether the hybrid technique yields superior outcomes in comparison with the total arch replacement combined with frozen elephant trunk (TAR + FET) for acute aortic dissection (AAD) involving the aortic arch.
Methods: This retrospective cohort study using propensity-score matching included patients with AAD involving the aortic arch admitted to Nanjing First Hospital and Shanghai General Hospital from January 2015 to June 2020. The in-hospital and mid-term outcomes were compared between patients who received hybrid treatment (n = 136) and those who received TAR + FET (n = 415).
Sci Rep
January 2025
Thoracic and Vascular Surgery Research Center, Namazi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran.
Abdominal Aortic Aneurysm (AAA) poses a significant health risk due to its silent nature and high mortality upon rupture. The Fib-4 index, initially designed for liver fibrosis assessment, presents potential beyond its scope. This study aims to investigate the association of FIB-4 with aneurysm size and mortality risk, exploring its utility as a risk predictor for enhanced clinical management.
View Article and Find Full Text PDFAnn Thorac Surg
January 2025
Department of Cardiac Surgery, University of Michigan, Ann Arbor, MI.
Background: The etiology of increased risk for reoperation after transcatheter aortic valve replacement (TAVR) versus prior surgical aortic valve replacement (SAVR) is poorly understood. This study evaluated the impact of concomitant mitral and tricuspid valve disease on associated risk of TAVR explant.
Methods: Patients undergoing aortic valve replacement after prior SAVR or TAVR were extracted from the Society of Thoracic Surgeons Adult Cardiac Surgery Database (2011-2021).
Ann Thorac Surg
January 2025
Department of Cardiovascular and Thoracic Surgery, West Virginia University, Morgantown, WV.
Background: As percutaneous therapeutic options expand, the optimal management of severe aortic stenosis (AS) and concomitant coronary artery disease (CAD) is being questioned between coronary artery bypass grafting and surgical aortic valve replacement (CABG+SAVR) versus percutaneous coronary intervention and transcatheter aortic valve replacement (PCI+TAVR). We sought to compare perioperative and longitudinal risk-adjusted outcomes between patients undergoing CABG+SAVR versus PCI+TAVR.
Methods: Using the United States Centers for Medicare and Medicaid Services inpatient claims database, we evaluated all patient age 65 and older with AS and CAD undergoing CABG+SAVR or PCI+TAVR (2018-2022).
Eur J Vasc Endovasc Surg
January 2025
Universitat Autònoma de Barcelona (UAB), Bellaterra, Spain; Vall d'Hebron Institut de Recerca (VHIR), Barcelona, Spain; Department of Vascular, Endovascular Surgery and Angiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain. Electronic address:
Objective: Abdominal aortic aneurysm (AAA) in a patient with an underlying heritable aortic disease (HAD) is rare, and evidence based recommendations for its management are lacking. This study aimed to generate a consensus from multidisciplinary specialists on the diagnosis, treatment, and surveillance of AAA associated with HAD and to define topics of interest for future research.
Methods: A Delphi consensus was designed involving European multidisciplinary specialists and reported using the ACcurate COnsensus Reporting Document (ACCORD) reporting guideline.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!