Background: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected.

Objective: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants.

Design: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness.

Setting: Six UK maternity units.

Participants: These were 20,055 asymptomatic newborns at ≥ 35 weeks' gestation, their mothers and health-care staff.

Interventions: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases).

Main Outcome Measures: Detection of major CHDs - defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis.

Results: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists.

Conclusions: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions.

Funding: The National Institute for Health Research Health Technology programme.

Download full-text PDF

Source
http://dx.doi.org/10.3310/hta16020DOI Listing

Publication Analysis

Top Keywords

pulse oximetry
40
major chds
28
chds
14
causing death
12
pulse
10
oximetry
9
oximetry screening
8
test
8
screening test
8
congenital heart
8

Similar Publications

Home Monitoring of High-Risk Individuals Receiving Opioids Post Orthopedic Surgery.

Respir Care

March 2025

Drs. Mazzola and Cloward are affiliated with Department of Sleep Medicine, Intermountain Health Care Inc, Murray, Utah, USA.

Postoperative patients receiving opioids are at risk for morbidity and mortality caused by opioid-induced respiratory depression (OIRD). Guidelines advocate electronic monitoring for OIRD during postoperative hospitalization, but the utility of home monitoring following ambulatory surgery has not been assessed. We describe the utilization of capnography and pulse oximetry in an ambulatory orthopedic cohort to determine subject/home caregiver acceptance and utility of continuous monitors at home.

View Article and Find Full Text PDF

Neonatal skin color, especially melanin assessment, remains an underexplored topic in neonatology and dermatology literature. Growing concerns about racial bias in pulse oximeters in adults highlight the need for objective assessment of skin color to investigate if skin pigmentation contributes to the inaccuracy. While skin color scales and cutaneous colorimetric devices have been utilized in adult dermatology for various applications, their use and effectiveness in neonates and infants are not well understood.

View Article and Find Full Text PDF

Lipid oxidation significantly affects the nutritional value and sensory properties of processed meat products. This study aimed to apply isothermal calorimetry to analyze the oxidation kinetics of fats from chicken, pork, lamb and speck at 40 °C in presence of 2,2'-Azobis(2-methylpropionitrile) (AIBN) radical initiator. Isothermal calorimetry allowed for continuous monitoring of the heat flow developed during the oxidation reaction determining key kinetic parameters such as the induction time (τ), rates of inhibited (R) and uninhibited (R) periods, and oxidizability index (O.

View Article and Find Full Text PDF

Aim: To assess the effect of oxygen reserve index (ORi)-guided titration of fraction of inspired oxygen (FiO2) on the incidence of postoperative delirium (POD) and the frequency of hyperoxemia episodes, assuming a potential link between hyperoxemia and POD.

Methods: This randomized controlled trial included 114 patients aged 65 years and older, scheduled for elective surgeries lasting over two hours at Health Sciences University Tepecik Training and Research Hospital between October 1, 2023, and July 7, 2024. Patients were randomized into the control group (n=57) or the ORi+pulse oximetry (SpO2) group (n=57).

View Article and Find Full Text PDF