The most recent Recommendations (Publication 103) issued by the International Commission for Radiological Protection (ICRP) are based on the data that have been published since 1990 up to now. The basic task of the ICRP Committee 1 was to formulate the key implications of studies on radiobiological effects for the purposes of radiological protection. Presented in the paper are the new achievements in the field of biology, radiobiology and radiation epidemiology which were taken into account by the ICRP in the process of Publication 103 preparation. The Recommendations provide present-day values of weighting factors for radiation exposure and tissue weighting factors, as well as radiation detriment and radiogenic risk factors for cancer and genetic diseases. Also considered are tissue reactions to radiation exposure, consequences of in utero exposure and the risks of developing non-cancer diseases for exposed individuals. It should be noted that the key inferences and recommendations are to a considerable degree related to biological effects accounted for by acute and chronic exposure to ionizing radiation in the range of small doses (up to 100 mSv).

Download full-text PDF

Source

Publication Analysis

Top Keywords

studies radiobiological
8
radiobiological effects
8
publication 103
8
radiological protection
8
weighting factors
8
radiation exposure
8
radiation
6
[principal inferences
4
inferences studies
4
effects radiation
4

Similar Publications

Very High-Energy Electron Therapy Toward Clinical Implementation.

Cancers (Basel)

January 2025

Intense Laser Irradiation Laboratory, National Institute of Optics, National Research Council of Italy, 56124 Pisa, Italy.

The use of very high energy electron (VHEE) beams, with energies between 50 and 400 MeV, has drawn considerable interest in radiotherapy due to their deep tissue penetration, sharp beam edges, and low sensitivity to tissue density. VHEE beams can be precisely steered with magnetic components, positioning VHEE therapy as a cost-effective option between photon and proton therapies. However, the clinical implementation of VHEE therapy (VHEET) requires advances in several areas: developing compact, stable, and efficient accelerators; creating sophisticated treatment planning software; and establishing clinically validated protocols.

View Article and Find Full Text PDF

Background: Re-irradiation in radiotherapy presents complexities that require dedicated tools to generate optimal re-treatment plans. This study presents a robust workflow that considers fractionation size, anatomical variations between treatments, and cumulative bias doses to improve the re-irradiation planning process.

Methods: The workflow was automated in MIM® Software and the Elekta© Monaco® treatment planning system.

View Article and Find Full Text PDF

Pancreatic cancer (PC) is one of the most aggressive and lethal malignancies, calling for enhanced research. Pancreatic ductal adenocarcinoma (PDAC) represents 70-80% of all cases and is known for its resistance to conventional therapies. Carbon-ion radiotherapy (CIRT) has emerged as a promising approach due to its ability to deliver highly localized doses and unique radiobiological properties compared to X-rays.

View Article and Find Full Text PDF

Ionizing radiation exposure during perinatal development can produce various biological effects on the developing offspring. These effects are dependent on a number of factors, including total dose, dose rate and the developmental processes occurring at the time of irradiation. The present study conducted an analysis of historical radiobiological archived data involving 60Co-gamma irradiation of beagle dogs at specific periods of prenatal or postnatal development.

View Article and Find Full Text PDF

Purpose: To evaluate the impact of patient setup errors on the dosimetry and radiobiological models of intensity-modulated radiotherapy (IMRT) for esophageal cancer.

Methods And Materials: This retrospective study with 56 patients in thermoplastic mask (TM) and vacuum bag (VB) groups utilized real setup-error (RSE) data from cone-beam CT scans to generate simulated setup-error (SSE) data following a normal distribution. The SSE data were applied to simulate all treatment fractions per patient by shifting the plan isocenter and recalculating the dose.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!