A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel pre-fractionation method of trans fatty acids by gas chromatography with silver-ion cartridge column. | LitMetric

We developed a novel pre-separation method of trans fatty acids (TFAs) using a silver-ion cartridge column and GC. As a preliminary study, a mixture of fatty acid methyl esters consisting of saturated, cis-unsaturated, and trans-unsaturated fatty acids was dissolved in dichloromethane and loaded onto a Bond Elut SCX ion-exchange cartridge column that was converted to the silver-ion form. The column was then eluted with dichloromethane to obtain the saturated fatty acids, dichloromethane/ethyl acetate (90/10) for the trans mono-ene, dichloromethane/ethyl acetate (65/35) for the cis mono-ene, dichloromethane/acetone (60/40) for the trans di-ene, and acetone/acetonitrile (80/20) for the others. Satisfactory separation of the cis/trans isomers was confirmed by GC analysis. To generalize this technique, the elution conditions of the ready-to-use Discovery Ag-ION SPE cartridge column were also optimized. Both cartridge columns had good separation, recovery, and repeatability. Peer laboratory verification was carried out between two laboratories using different production lots of the ready-to-use cartridge column, and the robustness of the product and reproducibility of the method were found to be satisfactory. This technique is therefore a powerful tool not only for routine analyses of TFAs in oils, fats, and foods but also for detailed analyses of TFAs in various research fields.

Download full-text PDF

Source
http://dx.doi.org/10.5650/jos.61.49DOI Listing

Publication Analysis

Top Keywords

cartridge column
20
fatty acids
16
method trans
8
trans fatty
8
silver-ion cartridge
8
dichloromethane/ethyl acetate
8
analyses tfas
8
cartridge
6
column
6
fatty
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!