The purpose of this study was to examine the effects of dynamic stretching on running energy cost and endurance performance in trained male runners. Fourteen male runners performed both a 30-minute preload run at 65% VO2max and a 30-minute time trial to assess running energy cost and performance, respectively. The subjects repeated both the trials after either 15 minutes of dynamic stretching (i.e., experimental condition) or quiet sitting (i.e., control condition) while the order was balanced between the subjects to avoid any order effect. The total calories expended were determined for the 30-minute preload run, whereas the distance covered was measured in the time trial. Average resting VO2 increased significantly (p < 0.05) after dynamic stretching (prestretch: 6.2 ± 1.7 vs. poststretch: 8.4 ± 2.1 ml·kg(-1)·min(-1)) but not during the quiet-sitting condition. Caloric expenditure was significantly higher during the 30-minute preload run for the stretching (416.3 ± 44.9 kcal) compared with that during the quiet sitting (399.3 ± 50.4 kcal) (p < 0.05). There was no difference in the distance covered after quiet sitting (6.3 ± 1.1 km) compared with that for the stretching condition (6.1 ± 1.3 km). These findings suggest that dynamic stretching does not affect running endurance performance in trained male runners.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1519/JSC.0b013e318225bbae | DOI Listing |
Sports Med
January 2025
School of Athletic Performance, Shanghai University of Sport, No. 200, Henren Road, Shanghai, 200438, China.
Background: Post-activation performance enhancement (PAPE) has demonstrated efficacy in acutely improving athletic performance. However, its distinction from general warm-up (GW) effects remains ambiguous, and experimental designs adopted in most PAPE studies exhibit important limitations.
Objectives: The aims of this work are to (i) examine the effects of research methodology on PAPE outcomes, (ii) explore PAPE outcomes in relation to comparison methods, performance measures, GW comprehensiveness, recovery duration, participants' characteristics, conditioning activity (CA) parameters, and (iii) make recommendations for future PAPE experimental designs on the basis of the results of the meta-analysis.
Cureus
December 2024
Rehabilitation Medicine, Spine Center, Bologna, ITA.
In the past two decades, interest in the fascial system has exponentially increased, particularly manual treatment and stretching exercises. The fascia's fundamental role remains the transmission of tensions, although this function can be impaired due to excessive or reduced stiffness. This second part of the work outlines the basic principles concerning the importance of appropriate and balanced fascial stiffness for correct postural and functional maintenance of the human body.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
January 2025
Shanghai Jiao Tong University, School of Chemistry and Chemical Engineering, 800 Dongchuan Road, 200240, Shanghai, CHINA.
Ionogels have attracted considerable attention as versatile materials due to their unique ionic conductivity and thermal stability. However, relatively weak mechanical performance of many existing ionogels has hindered their broader application. Herein, we develop robust, tough, and impact-resistant mechanically interlocked network ionogels (IGMINs) by incorporating ion liquids with mechanical bonds that can dissipate energy while maintain structural stability.
View Article and Find Full Text PDFNat Commun
January 2025
School of Electronics Science and Engineering/National Laboratory of Solid-State Microstructures, Nanjing University, Nanjing, China.
Ultrathin silicon nanowires (diameter <30 nm) with strong electrostatic control are ideal quasi-1D channel materials for high-performance field effect transistors, while a short channel is desirable to enhance driving current. Typically, the patterning of such delicate channels relies on high-precision lithography, which is not applicable for large area electronics. In this work, we demonstrate that ultrathin and short silicon nanowires channels can be created through a local-curvature-modulated catalytic growth, where a planar silicon nanowires is directed to jump over a crossing step.
View Article and Find Full Text PDFApproximately 800,000 total knee arthroplasties and 450,000 total hip arthroplasties are performed annually in the United States. These procedures provide significant pain relief and restore function in patients with advanced osteoarthritis, rheumatoid arthritis, and other degenerative joint conditions. Patient evaluation before surgery includes a history, physical examination, laboratory tests, and imaging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!