Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In response to Gulf of Mexico deepwater horizon oil spill, we have developed an atmospheric pressure photoionization (APPI) based ultra high performance liquid chromatography-mass spectrometry (UHPLC-MS) method for high-sensitivity analysis of United States Environmental Protection Agency (US EPA) 16 priority pollutant polynuclear aromatic hydrocarbons (PAHs) in oysters. Analyses were performed on an Agilent's Infinity 1290 UHPLC system coupled with a G6140A single quadrupole MS detector with Syagen's PhotoMate® APPI® source. Column separation was achieved using Zorbax Eclipse PAH column. Chlorobenzene was used as an APPI dopant for maximum overall sensitivity. Dynamic linear ranges were evaluated and found to cover 3.6-5.1 (Ave. 4.4) orders of magnitude with R² of at least 0.995. A quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction and cleanup procedure was used. The spike recoveries ranged from 77% to 110% with %RSD of 0.6-6.7 at spike concentrations below or substantially below the US Food and Drug Administration (FDA) level of concern in oysters. The on-column instrument detection limits (IDLs, 6σ S/N=3) ranged from 8 to 106 pg with an average of 23 pg for 16 PAHs. The method detection limits (MDLs, 6σ S/N=3) ranged from 0.013 to 0.129 ppm with an average of 0.040 ppm for all analytes. These MDLs were about 5 times to over 4 orders of magnitude lower than US FDA levels of concern in oysters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2011.12.111 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!