A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of different acids and etching times on the bond strength of glass fiber-reinforced composite root canal posts to composite core material. | LitMetric

Objective: To investigate the effects of different acids and etching times on the bond strength of glass fiber-reinforced composite (FRC) posts to composite core material.

Method And Materials: Twenty-six FRC posts (FRC Postec Plus) were randomly divided into 13 groups (each n = 2). One group received no surface treatment (control). The posts in the other groups were acid etched with 35% phosphoric acid and 5% and 9.6% hydrofluoric acid gel for four different etching times (30, 60, 120, and 180 seconds). A cylindric polytetrafluoroethylene mold was placed around the treated posts and filled with dual-cure composite core material (MultiCore Flow). All samples were light cured for 60 seconds. After 24 hours of water storage, the specimens were sectioned perpendicularly to the bonded interface under water cooling to obtain 2-mm post-and-core specimens. Eight specimens were made from each group. Push-out tests were performed at a crosshead speed of 0.5 mm/min using a universal testing machine. Data were analyzed by one-way ANOVA followed by the Tukey honestly significant difference test (alpha = .05).

Results: The lowest bond strength was observed in the control group (12.51 megapascal [MPa]). No statistical significant difference was observed among group H5-120 (20.31 MPa), group H9-120 (20.55 MPa), or group P-180 (20.57 MPa) (P > .05). These groups demonstrated the highest bond strength values (P < .05).

Conclusion: For the FRC posts, all acid-etching procedures tested showed significantly increased bond strength when compared with the control group. Acid-etching with 5% hydrofluoric acid and 9.6% hydrofluoric acid for 2 minutes and with 35% phosphoric acid for 3 minutes (groups H5-120, H9-120, and P-180, respectively) demonstrated the highest bond strength values between the FRC post and composite core material. Although the bond strength was increased by prolonged acid etching, the microstructure of the FRC posts might have been damaged.

Download full-text PDF

Source

Publication Analysis

Top Keywords

bond strength
28
composite core
16
frc posts
16
etching times
12
core material
12
hydrofluoric acid
12
effects acids
8
acids etching
8
times bond
8
strength glass
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!