Rapid and accurate detection of norovirus is essential for the prevention and control of norovirus outbreaks. This study compared the effectiveness of a new immunochromatographic assay kit (SD BIOLINE Norovirus; Standard Diagnostics, Korea) and real-time reverse transcription-PCR (RT-PCR) for detecting norovirus in fecal specimens. Compared with real-time RT-PCR, the new assay had sensitivity, specificity, positive predictive value, and negative predictive value of 76.5% (52/68), 99.7% (342/343), 98.1% (52/53), and 95.5% (342/358), respectively. The sensitivity of the assay was 81.8% (18/22) for GII.3 and 75.7% (28/37) for GII.4. None of the 38 enteric virus-positive specimens (3 for astrovirus, 5 for enteric adenovirus, and 30 for rotavirus) tested positive in the cross-reactivity test performed by using this assay. The new immunochromatographic assay may be a useful screening tool for the rapid detection of norovirus in sporadic and outbreak cases; however, negative results may require confirmatory assays of greater sensitivity.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3255496 | PMC |
http://dx.doi.org/10.3343/alm.2012.32.1.79 | DOI Listing |
Sci Rep
January 2025
Department of Laboratory Medicine, the Affiliated Hospital of Inner Mongolia Medical University, Hohhot, China.
Previous studies have suggested that the presence of human epididymal protein 4 (HE4) in pleural fluid can be used to diagnose malignant pleural effusion (MPE) with moderate accuracy. However, the factors that affect the diagnostic accuracy of HE4 remain unknown. This study aimed to examine how age and sex influence the diagnostic accuracy of HE4.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Life Technologies, Division of Biotechnology, University of Turku, Medisiina D, 5th floor, Kiinamyllynkatu 10, 20520, Turku, Finland.
Glycosylation changes of circulating proteins carrying the CA19-9 antigen may offer new targets for detection methods to be explored for the diagnosis of epithelial ovarian cancer (EOC). Search for assay designs for targets initially captured by a CA19-9 antigen reactive antibody from human body fluids by probing with fluorescent nanoparticles coated with lectins or antibodies to known EOC associated proteins. CA19-9 antigens were immobilized from ascites fluids, ovarian cyst fluids or serum samples using monoclonal antibody C192 followed by probing of carrier proteins using anti-MUC16, anti-MUC1 and, anti STn antibodies and seven lectins, all separately coated on nanoparticles.
View Article and Find Full Text PDFLancet
January 2025
Centre for Inflammatory Disease, Department of Immunology and Inflammation, Imperial College London, London, UK; Imperial College Renal and Transplant Centre, Imperial College Healthcare NHS Trust, Hammersmith Hospital, London, UK. Electronic address:
Background: In the UK, booster COVID-19 vaccinations have been recommended biannually to people considered immune vulnerable. We investigated, at a population level, whether the absence of detectable anti-SARS-CoV-2 spike protein IgG antibody (anti-S Ab) following three or more vaccinations in immunosuppressed individuals was associated with greater risks of infection and severity of infection.
Methods: In this prospective cohort study using UK national disease registers, we recruited participants with solid organ transplants (SOTs), rare autoimmune rheumatic diseases (RAIRDs), and lymphoid malignancies.
Anal Chim Acta
February 2025
The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, No. 28 Xianning West Road, Xi'an, 710049, China. Electronic address:
Background: Plasmonic core-shell nanostructures with embedded internal markers used as Raman probes have attracted great attention in surface-enhanced Raman scattering (SERS) immunoassay for cancer biomarkers due to their excellent uniform enhancement. However, current core-shell nanostructures typically exhibit a spherical shape and are coated with a gold shell, resulting in constrained local field enhancement.
Results: In this work, we prepared a core-shell AuNR@BDT@Ag structure by depositing silver on the surface of Raman reporter-modified gold nanorods (AuNR).
Anal Chim Acta
February 2025
School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China; Department of Chemistry, Sungkyunkwan University, Suwon, 16419, Republic of Korea. Electronic address:
Background: Estriol (E3) is a common estrogen responsible for regulating the female reproductive system, but excessive amount can pose health risks to humans and wild life. Therefore, sensitive and accurate detection of estriol level is crucial. A novel competitive ECL immunosensor based on a dual signal amplification strategy of AuNPs@GO@SmMoSe and Gd(MoO) was fabricated for ultrasensitive detection of estriol.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!