We have investigated the precision of peptide quantitation by MALDI-TOF mass spectrometry (MS) using six pairs of proteotypic peptides (light) and same-sequence stable isotope labeled synthetic internal standards (heavy). These were combined in two types of dilution curves spanning 100-fold and 2000-fold ratios. Coefficients of variation (CV; standard deviation divided by mean value) were examined across replicate MALDI spots using a reflector acquisition method requiring 100 000 counts for the most intense peak in each summed spectrum. The CV of light/heavy peptide centroid peak area ratios determined on four replicate spots per sample, averaged across 11 points of a 100-fold dilution curve and over all six peptides, was 2.2% (ranging from 1.5 to 3.7% among peptides) at 55 fmol total (light + heavy) of each peptide applied per spot, and 2.5% at 11 fmol applied. The average CV of measurements at near-equivalence (light = heavy, the center of the dilution curve) for the six peptides was 1.0%, about 17-fold lower CV than that observed when five peptides were ratioed to a sixth peptide (i.e., a different-sequence internal standard). Response curves across the 100-fold range were not completely linear but could be closely modeled by a power law fit giving R(2) values >0.998 for all peptides. The MALDI-TOF MS method was used to determine the endogenous level of a proteotypic peptide (EDQYHYLLDR) of human protein C inhibitor (PCI) in a plasma digest after enrichment by capture on a high affinity antipeptide antibody, a technique called stable isotope standards and capture by anti-peptide antibodies (SISCAPA). The level of PCI was determined to be 770 ng/mL with a replicate measurement CV of 1.5% and a >14 000-fold target enrichment via SISCAPA-MALDI-TOF. These results indicate that MALDI-TOF technology can provide precise quantitation of high-to-medium abundance peptide biomarkers over a 100-fold dynamic range when ratioed to same-sequence labeled internal standards and enriched to near purity by specific antibody capture. The robustness and throughput of MALDI-TOF in comparison to conventional nano-LC-MS technology could enable currently impractical large-scale verification studies of protein biomarkers.

Download full-text PDF

Source
http://dx.doi.org/10.1021/pr201092vDOI Listing

Publication Analysis

Top Keywords

maldi-tof mass
8
mass spectrometry
8
stable isotope
8
internal standards
8
dilution curve
8
curve peptides
8
light heavy
8
peptide
7
peptides
6
maldi-tof
5

Similar Publications

Analytical thin layer chromatography (TLC) is a simple yet powerful chromatographic technique that is widely used for the qualitative characterization of complex mixtures such as plant extracts. For their qualitative and visual characterisation, a large number of more or less specific colour reactions are at hand and numerous reference substances are available as well. However, the identification of extract components by colour and the comparison of retention times is not straightforward.

View Article and Find Full Text PDF

Endophthalmitis is a serious infectious eye disease that causes permanent vision loss. This study developed a method for rapid identification and drug resistance analysis of pathogens in vitreous humor. After short-term rapid culture, 30 Staphylococcus aureus isolates were enriched and purified from the vitreous humor using Fc-MBL@FeO, and then identified by MALDI-TOF MS.

View Article and Find Full Text PDF

Objective: Staphylococcus aureus (SA), including methicillin-resistant strains (MRSAs), is a major cause of skin and soft tissue infections (SSTIs) in military populations. This study investigated SSTI incidence and SA carriage in a military training site over 16 weeks using a prospective observational cohort design.

Methods: Two training cohorts provided pre- and post-training self-collected swabs for bacterial carriage, and environmental swabs from accommodations, personal items, and training facilities.

View Article and Find Full Text PDF

Evaluation of a New Tandem Mass Spectrometry Method for Sickle Cell Disease Newborn Screening.

Int J Neonatal Screen

November 2024

Laboratoire de Biologie Médicale Multi-Sites (LBMMS), Service de Biochimie et Biologie Moléculaire Grand Est, Hospices Civils de Lyon, 69500 Bron, France.

In France, sickle cell disease newborn screening (SCD NBS) has been targeted to at-risk regions since 1984, but generalization to the whole population will be implemented from November 2024. Although tandem mass spectrometry (MS/MS) is already used for the NBS of several inherited metabolic diseases, its application for SCD NBS has not been widely adopted worldwide. The aim of this study was to evaluate a dedicated MS/MS kit (Targeted MS/MS Hemo, ZenTech, LaCAR Company, Liege, Belgium) for SCD NBS and to compare the results obtained with those from an NBS reference center using matrix-assisted laser desorption/ionization time of flight (MALDI-TOF) and cation-exchange high-performance liquid chromatography (CE-HPLC, Variant NBS, Biorad Laboratories, Inc.

View Article and Find Full Text PDF

Rationale: Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) is a powerful method for identifying viruses via nucleic acid detection. The data processing method is critical in recognizing nucleic acid obtained by MALDI-TOF-MS. Therefore, new development of data algorithm is needed for virus identification.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!