A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Subtle grip force estimation from EMG and muscle stiffness--relationship between muscle character frequency and grip force. | LitMetric

Subtle grip force estimation from EMG and muscle stiffness--relationship between muscle character frequency and grip force.

Annu Int Conf IEEE Eng Med Biol Soc

Graduate School of Advanced Science and Engineering, Waseda University, Tokyo 169-8555, Japan.

Published: July 2012

A number of upper limb amputees experience difficulty in picking up a food bowl during a meal, because grip force estimation using EMG currently does not provide sufficient accuracy for this task. In this paper, we propose a grip force estimation system that allows amputees to pick up a bowl with a prosthetic hand by using the properties of muscle stiffness in addition to EMG. We have chosen a tray holding task to evaluate the proposed system. A weight is dropped on the tray and the subjects are expected to control the tray's attitude during the task. Actual grip force, EMG, and muscle stiffness are measured, and the actual measured grip force is compared with the estimated grip force for evaluation. As a result, the proposed algorithm is found to be able to estimate grip force with an error of just 18[N], which is 30% smaller than in the method that uses only EMG. From the result that the response time estimated by proposed system is even less than a human's mechanical reaction time, the effectiveness of the proposed method has been validated.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2011.6091022DOI Listing

Publication Analysis

Top Keywords

grip force
32
force estimation
12
force
8
estimation emg
8
emg muscle
8
muscle stiffness
8
proposed system
8
grip
7
emg
5
subtle grip
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!