A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spectral features of electroencephalogram in characterizing various brain states under anesthesia. | LitMetric

Spectral features of electroencephalogram in characterizing various brain states under anesthesia.

Annu Int Conf IEEE Eng Med Biol Soc

Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9 Canada.

Published: June 2012

The administration of the anesthetic agents is known to alter the electroencephalogram (EEG) signal significantly with the brain being their primary target. In this study, we analyzed the EEG recorded from six ASA I/II patients undergoing a 1-2 hour surgery. The EEG was collected before and during induction, maintenance and recovery of anesthesia using the 10/20 lead-system. A combination of fentanyl and propofol (± rocuronium) was used for induction and a Sevoflurane in air/O(2) mixture was administered through an endotracheal tube to achieve the steady minimum alveolar concentration (MAC). This study showed that 0 to 4 Hz signal power was most sensitive to the changes associated with induction of anesthesia whereas the 4 to 12 Hz power was important in classifying states during maintenance of anesthesia. Anesthesia also promoted heightened phase coherence in 8 to 16 Hz and 16 to 30 Hz ranges during maintenance and induction of anesthesia, respectively. Additionally, strong cross-frequency coupling between 7 to 20 Hz and 10 to 40 Hz was observed during anesthesia suggesting alteration of neural coding.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2011.6090846DOI Listing

Publication Analysis

Top Keywords

induction anesthesia
8
anesthesia
7
spectral features
4
features electroencephalogram
4
electroencephalogram characterizing
4
characterizing brain
4
brain states
4
states anesthesia
4
anesthesia administration
4
administration anesthetic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!