Towards unified electromagnetic tracking system assessment-static errors.

Annu Int Conf IEEE Eng Med Biol Soc

Dept of Control Engineering and Information Technology, Budapest University of Technology and Economics, Magyar tudósok krt 2, Budapest, Hungary.

Published: June 2012

Recent advances in Image-Guided Surgery allows physicians to incorporate up-to-date, high quality patient data in the surgical decision making, and sometimes to directly perform operations based on pre- or intra-operatively acquired patient images. Electromagnetic tracking is the fastest growing area within, where the position and orientation of tiny sensors can be determined with sub-millimeter accuracy in the field created by a generator. One of the major barriers to the wider spread of electromagnetic tracking solutions is their susceptibility to ferromagnetic materials and external electromagnetic sources. The research community has long been engaged with the topic to find engineering solutions to increase measurement reliability and accuracy. This article gives an overview of related experiments, and presents our recommendation towards a robust method to collect representative data about electromagnetic trackers.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2011.6090539DOI Listing

Publication Analysis

Top Keywords

electromagnetic tracking
12
unified electromagnetic
4
tracking system
4
system assessment-static
4
assessment-static errors
4
errors advances
4
advances image-guided
4
image-guided surgery
4
surgery allows
4
allows physicians
4

Similar Publications

Background: Metastatic retroperitoneal lymph node dissection (LND) for nodal recurrence is applied for a variety of cancers, such as urological, gynaecological and rectal cancer. Precise localisation and resection of these lymph nodes (LNs) during surgery can be challenging, especially after previous radiotherapy or surgery. The objective of this study was to assess the added value of surgical navigation for targeted LND in the retroperitoneum.

View Article and Find Full Text PDF

Wearable nanocomposite stretch sensors are an exciting new development in biomaterials for biomechanical motion-tracking technology, with applications in the treatment of low back pain, knee rehabilitation, fetal movement tracking, and other fields. When strained, the resistance of the low-cost sensors is reduced, enabling human motion to be monitored using a suitable sensor array. However, current sensor technologies have exhibited significant drift, in the form of increased electrical resistance, if left stored in typical room conditions.

View Article and Find Full Text PDF

Electrical Bioimpedance-Based Monitoring of Intracochlear Tissue Changes After Cochlear Implantation.

Sensors (Basel)

November 2024

Department of Otorhinolaryngology, Head & Neck Surgery, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland.

Background: This study examined electrical bioimpedance as a biomarker for intracochlear tissue changes after cochlear implant surgery, comparing monopolar, three-point, and four-point impedance measurements over time and evaluating different measurement systems and approaches.

Methods: Impedance measurements were obtained from 21 participants during surgery and at four postoperative stages. Monopolar impedances were recorded using the Bionic Ear Data Collection System (BEDCS) and the Active Insertion Monitoring (AIM) system.

View Article and Find Full Text PDF

Photonic Band Gap Engineering by Varying the Inverse Opal Wall Thickness.

Int J Mol Sci

December 2024

Institute of Physical Metallurgy, Metal Forming and Nanotechnology, University of Miskolc, H-3515 Miskolc, Hungary.

We demonstrate the band gap programming of inverse opals by fabrication of different wall thickness by atomic layer deposition (ALD). The opal templates were synthesized using polystyrene and carbon nanospheres by the vertical deposition method. The structure and properties of the TiO inverse opal samples were investigated using Scanning Electron Microscope (SEM) and Focused Ion Beam Scanning Electron Microscopy (FIB-SEM), Energy Dispersive X-ray analysis (EDX), X-ray Diffraction (XRD) and Finite Difference Time Domain (FDTD) simulations.

View Article and Find Full Text PDF

Tracking head movement inside an MR scanner using electromagnetic coils.

Heliyon

July 2024

Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, NG7 2RD, UK.

Prospective motion corrections in brain imaging for MRI are fairly challenging. Monitoring involuntary head movement inside MR scanner is crucial for prospective motion correction. This initial study delves into utilizing simulations to track the head's movements within an MRI scanner, achieved by measuring induced voltage changes from time-varying magnetic field gradients in head-mounted coils.

View Article and Find Full Text PDF