The robot described in this paper, SUE (Supinator Extender), adds forearm/wrist rehabilitation functionality to the UCI BONES exoskeleton robot and to the ArmeoSpring rehabilitation device. SUE is a 2-DOF serial chain that can measure and assist forearm supination-pronation and wrist flexion-extension. The large power to weight ratio of pneumatic actuators allows SUE to achieve the forces needed for rehabilitation therapy while remaining lightweight enough to be carried by BONES and ArmeoSpring. Each degree of freedom has a range of 90 degrees, and a nominal torque of 2 ft-lbs. The cylinders are mounted away from the patient's body on the lateral aspect of the arm. This is to prevent the danger of a collision and maximize the workspace of the arm robot. The rotation axis used for supination-pronation is a small bearing just below the subject's wrist. The flexion-extension motion is actuated by a cantilevered pneumatic cylinder, which allows the palm of the hand to remain open. Data are presented that demonstrate the ability of SUE to measure and cancel forearm/wrist passive tone, thereby extending the active range of motion for people with stroke.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/IEMBS.2011.6090459 | DOI Listing |
Indian Pacing Electrophysiol J
January 2015
Division of Cardiovascular Diseases, Mayo Clinic, Rochester, MN.
A 53-year-old man underwent implantation of a totally subcutaneous ICD (S-ICD; Boston Scientific). He was positioned supine, with the left arm abducted, externally rotated (i.e.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
June 2012
University of California Irvine, CA 92697, USA.
The robot described in this paper, SUE (Supinator Extender), adds forearm/wrist rehabilitation functionality to the UCI BONES exoskeleton robot and to the ArmeoSpring rehabilitation device. SUE is a 2-DOF serial chain that can measure and assist forearm supination-pronation and wrist flexion-extension. The large power to weight ratio of pneumatic actuators allows SUE to achieve the forces needed for rehabilitation therapy while remaining lightweight enough to be carried by BONES and ArmeoSpring.
View Article and Find Full Text PDFMagn Reson Med Sci
February 2008
Department of Radiology, Osaka Seamen's Insurance Hospital, Osaka, japan.
Purpose: We assessed the diagnostic value of whole body magnetic resonance (MR) imaging (WB-MRI) using diffusion-weighted images (DWI) for detecting bone metastasis and compared it with that of skeletal scintigraphy (SS).
Materials And Methods: Thirty patients with malignancies (breast cancer, 17 patients; prostate cancer, 9; and one patient each, thyroid cancer, liposarcoma, leiomyosarcoma, and extraskeletal Ewing sarcoma) underwent both WB-MRI and SS to detect bone metastasis. All patients were followed more than 6 months by MR imaging, SS, or computed tomographic (CT) examination.
Radiother Oncol
December 1987
Department of Radiation Therapy, Johannesburg Hospital, University of the Witwatersrand, South Africa.
A study of the mantle technique for Hodgkins disease patients was embarked upon using thermoluminescent dosimetry (TLD) and a RANDO phantom. There was concern that the technique using Co-60 and turning the patient over for the posterior field may not be optimal as it was felt that the axillary areas of these patients were being under-dosed. A variety of treatment set-ups were performed on a 60-Cobalt unit at extended SSD.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!