ISO/IEEE 11073 PHD message generation toolkit to standardize healthcare device.

Annu Int Conf IEEE Eng Med Biol Soc

Life-technology Research Team, Electronics and Telecommunication Research Institute, Gajeong-Dong, Yuseong-Gu, Daejeon 305-700, Korea.

Published: June 2012

As senior population increases, various healthcare devices and services are developed such as fall detection device, home hypertension management service, and etc. However, to vitalize healthcare devices and services market, standardization for interoperability between device and service must precede. To achieve the standardization goal, the IEEE 11073 Personal Health Device (PHD) group has been standardized many healthcare devices, but until now there are few devices compatible with the PHD standard. One of main reasons is that it isn't easy for device manufactures to implement standard communication module by analyzing standard documents of over 600 pages. In this paper, we propose a standard message generation toolkit to easily standardize existing non-standard healthcare devices. The proposed toolkit generates standard PHD messages using inputted device information, and the generated messages are adapted to the device with the standard state machine file. For the experiments, we develop a reference H/W, and test the proposed toolkit with three healthcare devices: blood pressure, weighting scale, and glucose meter. The proposed toolkit has an advantage that even if the user doesn't know the standard in detail, the user can easily standardize the non-standard healthcare devices.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2011.6090272DOI Listing

Publication Analysis

Top Keywords

healthcare devices
24
proposed toolkit
12
message generation
8
generation toolkit
8
devices services
8
easily standardize
8
non-standard healthcare
8
healthcare
7
device
7
devices
7

Similar Publications

Introduction: Wearables are electronic devices worn on the body to collect health data. These devices, like smartwatches and patches, use sensors to gather information on various health parameters. This review highlights current use and the potential benefit of wearable technology in patients with inflammatory bowel disease (IBD).

View Article and Find Full Text PDF

Excessive Initial Renal Function Decline Following Sodium-Glucose Cotransporter-2 Inhibitor Treatment Predicts Major Adverse Cardiorenal Outcomes.

Mayo Clin Proc

January 2025

Division of Nephrology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan; School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan; Department and Institute of Physiology, National Yang Ming Chiao Tung University, Taipei, Taiwan; Center For Intelligent Drug Systems and Smart Bio-devices (IDS(2)B) National Yang Ming Chiao Tung University, Hsinchu, Taiwan. Electronic address:

Objective: To investigate how estimated glomerular filtration rate (eGFR) decline following sodium-glucose cotransporter-2 inhibitors (SGLT2i) initiation predicts long-term cardiorenal outcomes.

Methods: From 2016 to 2020, a longitudinal cohort of 4942 diabetic patients treated with SGLT2i were enrolled and followed until December 2021. Patients were categorized into mild (≤30%), moderate (>30%∼≤40%) and severe (>40%) decline groups by the maximal eGFR change between 2 to 12 weeks after SGLT2i treatment.

View Article and Find Full Text PDF

The PERFORMANCE II Trial: A Prospective Multicenter Investigation of a Novel Carotid Stent System.

JACC Cardiovasc Interv

December 2024

Department for Angiology, Brandenburg Medical School Theodor Fontane, Campus Clinic Brandenburg, Center for Internal Medicine I, Berlin, Germany; Department of Angiology, Sankt-Gertrauden-Krankenhaus, Berlin, Germany.

Background: Several randomized clinical trials have shown that the composite endpoint of death, stroke, and myocardial infarction (MI) is equivalent between carotid artery stenting and carotid endarterectomy. However, the risk of minor stroke has been consistently higher with carotid artery stenting.

Objectives: The authors sought to evaluate the safety and effectiveness of a novel carotid stent system comprised of a stent, an adjustable integrated embolic filter and a postdilation balloon, in patients at elevated risk for adverse events from carotid endarterectomy.

View Article and Find Full Text PDF

Fiber-based strain sensors, as wearable integrated devices, have shown substantial promise in health monitoring. However, current sensors suffer from limited tunability in sensing performance, constraining their adaptability to diverse human motions. Drawing inspiration from the structure of the spiranthes sinensis, this study introduces a unique textile wrapping technique to coil flexible silver (Ag) yarn around the surface of multifilament elastic polyurethane (PU), thereby constructing a helical structure fiber-based strain sensor.

View Article and Find Full Text PDF

Introduction: This analysis aimed to investigate diabetes-specific psychological outcomes among adults with type 1 diabetes (T1D) using hybrid closed-loop (HCL) versus standard therapy.

Research Design And Methods: In this multicenter, open-label, randomized, controlled, parallel-group clinical trial, adults with T1D were allocated to 26 weeks of HCL (MiniMed™ 670G) or standard therapy (insulin pump or multiple daily injections without real-time continuous glucose monitoring). Psychological outcomes (awareness and fear of hypoglycemia; and diabetes-specific positive well-being, diabetes distress, diabetes treatment satisfaction, and diabetes-specific quality of life (QoL)) were measured at enrollment, mid-trial and end-trial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!