Denoising and harmonic artifacts rejection for ECG P-waves by quadratic variation reduction.

Annu Int Conf IEEE Eng Med Biol Soc

Faculty of Engineering, Università Campus Bio-Medico di Roma, via Álvaro del Portillo 21, 00128 Rome, Italy.

Published: June 2012

Atrial fibrillation (AF) is a common cardiac arrhythmia related to irregular atrial contractions. Several studies have shown that the analysis of P-waves extracted from ECG signals is helpful in understanding the predisposing factors to AF. However, P-waves are usually highly corrupted by noise and harmonic artifacts and this makes quite difficult their analysis. Recently we proposed a novel algorithm for denoising P-waves based on the notion of quadratic variation reduction. It is quite good in denoising P-waves affected by noise, but its effectiveness reduces when it is used in filtering out harmonic artifacts, like power-line interference. In this paper we propose an algorithm that overcomes this limitation and extends our previous method allowing it to both denoise and reject harmonic artifacts. Simulation results confirm the effectiveness of the approach and highlight its ability to remove both noise and artifacts. The algorithm has reduced computational complexity and this makes it suitable for real-time applications.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2011.6090222DOI Listing

Publication Analysis

Top Keywords

harmonic artifacts
16
quadratic variation
8
variation reduction
8
denoising p-waves
8
artifacts
5
p-waves
5
denoising harmonic
4
artifacts rejection
4
rejection ecg
4
ecg p-waves
4

Similar Publications

Anomalous pressure-density relations and speed of sound in bubbly water systems.

J Chem Phys

November 2024

Department of Chemistry and Chemical Theory Center, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455-0431, USA.

The speed of sound in bubbly water is an important parameter in the wave equations governing pressure-density relations for turbulent multi-phase flow simulations. Recent molecular simulation results indicate that, for bubbles that are thermodynamically stable at finite volume conditions, the derivative of total pressure P with density ρ has a negative sign, complicating the interpretation of the speed of sound. We show that such a negative compressibility is thermodynamically consistent in a single-component two-phase model at finite volume, and identify an empirically derived equation of state to illustrate that this observation is not an artifact of small simulation length scales.

View Article and Find Full Text PDF

The dynamic range of non-coherent continuous-wave (CW) THz photomixing (PM) systems with broadband detectors can be significantly limited by various parasitic effects. Specifically, we examine the generation of parasitic (i) THz and (ii) IR radiation, and (iii) higher harmonics in CW THz PM emitters. (i) The parasitic broadband THz radiation, spanning from 100 to 250 GHz with a total output power of 20 nW, results from not perfectly clean laser spectra.

View Article and Find Full Text PDF

We present a 2.5-mm-diameter resonant fiber scanning two-photon microendoscope with a 30-mm long forward-viewing rigid probe tip that enables video-rate imaging (20 Hz frame rate) suitable for hand-held imaging of tissues without motion artifacts. Higher-order harmonic oscillation scanning techniques are developed to significantly increase the frame rate compared to prior published fiber scanning microendoscopy designs while maintaining the field-of-view (∼125 µm), the optical resolution (1.

View Article and Find Full Text PDF

Recently, two-dimensional terahertz spectroscopy (2DTS) has attracted increasing attention for studying complex solids. A number of recent studies have applied 2DTS either with long pulses or away from any material resonances, situations that yield unconventional 2DTS spectra that are often difficult to interpret. Here, we clarify the generic origins of observed spectral features by examining 2DTS spectra of ZnTe, a model system with a featureless optical susceptibility at low terahertz frequencies.

View Article and Find Full Text PDF

The development of microrobots for biomedical applications has enabled tasks such as targeted drug delivery, minimally invasive surgeries, and precise diagnostics. However, effective in vivo navigation and control remain challenging due to their small size and complex body environment. Photoacoustic (PA) and ultrasound (US) imaging techniques, which offer high contrast, high resolution, and deep tissue penetration, are integrated to enhance microrobot visualization and tracking.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!