DNP in MRI: an in-bore approach at 1.5 T.

J Magn Reson

Institute of Physical and Theoretical Chemistry and Center of Biomolecular Magnetic Resonance, Goethe University Frankfurt, Max-von-Laue-Str. 7, 60438 Frankfurt, Germany.

Published: February 2012

We have used liquid state ("Overhauser") Dynamic Nuclear Polarization (DNP) to significantly enhance the signal to noise ratio (SNR) of Magnetic Resonance Imaging (MRI). For the first time this was achieved by hyperpolarizing directly in the MRI-scanner field of 1.5 T in continuous flow mode and immediately delivering the hyperpolarized substance to the imaging site to ensure maximum contrast between hyperpolarized sample and sample at thermal polarization. We achieve a maximum absolute signal enhancement factor of 98; while the hyperpolarized sample is transported at a flow rate of up to 30 ml/h yielding an average flow speed up to 470 mm/s over a distance of approximately 80 mm. A spatial imaging resolution of 100 μm with a signal to noise ratio of 25 was achieved on the flowing sample. Application to MRI contrast enhancement or microfluidic imaging can be envisaged immediately.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2011.12.015DOI Listing

Publication Analysis

Top Keywords

signal noise
8
noise ratio
8
hyperpolarized sample
8
dnp mri
4
mri in-bore
4
in-bore approach
4
approach liquid
4
liquid state
4
state "overhauser"
4
"overhauser" dynamic
4

Similar Publications

A modified adaptive Kalman filter (AKF) algorithm is proposed to make underwater multi-target tracking with uncertain measurement noise reliable. By utilizing the proposed AKF algorithm with three core points, including an adaptive fading factor, measurement noise covariance adjustment, and an adaptive weighting factor, the unknown measurement noise and state vector can be estimated with good accuracy and robustness. The practical trial data verify this algorithm, and it has proven superior to all traditional algorithms in this Letter based on the results that it reduces the estimated position RMSEs by at least 10.

View Article and Find Full Text PDF

Carbon fiber reinforced polymers (CFRPs) are widely used in fields such as aviation and aerospace. However, subtle defects can significantly impact the material's service life, making defect detection a critical priority. In this paper, delamination defects in CFRP are detected using line laser infrared thermography, and a defect characterization algorithm that combines differential thermography with a frequency-domain filter is proposed.

View Article and Find Full Text PDF

Capacitive sensors are commonly used in superconducting gravimeters due to their high resolution and low drift. This study developed a cryogenic front-end circuit for superconducting gravimeters to reduce the negative effects of parasitic capacitance on capacitive sensors. The front-end circuit comprises a noiseless superconducting transformer and a low-noise cryogenic preamplifier, both of which are positioned adjacent to the capacitive sensor probe.

View Article and Find Full Text PDF

Purpose: The aim of the study was to investigate the value of SwiftScan Step-and-Shoot Continuous (SSC) scanning mode in enhancing image quality and to explore appropriate scanning parameters for reducing scan time.

Methods: This study was composed of a phantom study and two clinical tests. The differences in visual image quality scores, coefficient of variance (COV) of the background, image signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and recovery coefficient (RC) of the sphere were compared between SSC mode and traditional Step-and-Shoot (SS) mode in the phantom study.

View Article and Find Full Text PDF

Tracking Somatic Mutations for Lineage Reconstruction.

Methods Mol Biol

January 2025

Department of Computer Science and Applied Mathematics, Weizmann Institute of Science, Rehovot, Israel.

The human genome is composed of distinct genomic regions that are susceptible to various types of somatic mutations. Among these, Short Tandem Repeats (STRs) stand out as the most mutable genetic elements. STRs are short repetitive polymorphic sequences, predominantly situated within noncoding sectors of the genome.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!