CARTOS II semi-automated nerve tracing: three-dimensional reconstruction from serial section micrographs.

Comput Med Imaging Graph

Biology Department, Columbia University, New York, NY 10027.

Published: December 1990

The paper describes the history of tracing activities in the Levinthal lab from 1965 to the present. It also focuses on the evolution of electron micrograph (EM) tracing from early hand tracing reconstruction to the current, nearly fully automated CARTOS II tracing system. The present hardware systems and tracing algorithms are described in detail. Also presented are the partial tracing results of one EM data set in two and three dimensions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0895-6111(90)90106-lDOI Listing

Publication Analysis

Top Keywords

tracing
7
cartos semi-automated
4
semi-automated nerve
4
nerve tracing
4
tracing three-dimensional
4
three-dimensional reconstruction
4
reconstruction serial
4
serial micrographs
4
micrographs paper
4
paper describes
4

Similar Publications

Developing a reliable procedure for the growth of III-V nanowires (NW) on silicon (Si) substrates remains a significant challenge, as current methods rely on trial-and-error approaches with varying interpretations of critical process steps such as sample preparation, Au-Si alloy formation in the growth reactor, and nanowire alignment. Addressing these challenges is essential for enabling high-performance electronic and optoelectronic devices that combine the superior properties of III-V NW semiconductors with the well-established Si-based technology. Combining conventional scalable growth methods, such as Metalorganic Chemical Vapor Deposition (MOCVD) with in situ characterization using Environmental Transmission Electron Microscopy (ETEM-MOCVD) enables a deeper understanding of the growth dynamics, if that knowledge is transferable to the scalable processes.

View Article and Find Full Text PDF

Direct Frequency Comb Cavity Ring-Down Spectroscopy Using Vernier Filtering.

J Phys Chem A

January 2025

Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, United States.

We present direct frequency comb cavity ring-down spectroscopy with Vernier filtering as a straightforward approach to sensitive and multiplexed trace gas detection. The high finesse cavity acts both to extend the interaction length with the sample and as a spectral filter, alleviating the need for dispersive elements or an interferometer. In this demonstration, a free running interband cascade laser was used to generate a comb centered at 3.

View Article and Find Full Text PDF

Bacterial endospores are ubiquitous and are responsible for various human infections. Recently, we reported that an ionic liquid (IL)-based sample preparation method (named pTRUST) facilitated highly efficient shotgun analysis of the Bacillus subtilis spore proteome in trace samples. In this study, we evaluated the efficiency and applicability of the pTRUST technology using three different spore preparations: one purified from the closely related subspecies B.

View Article and Find Full Text PDF

The reliability of cardiotocographs as diagnostic tools for fetal well-being is hampered by interpretational variations among healthcare professionals, contributing to high rates of cesarean sections and instrumental deliveries. While adjunct technologies may be used to confirm cases of fetal distress, those in resource constrained areas continue to rely on visual cardiotocograph interpretation to come up with the diagnosis of fetal hypoxia. This study investigated the factors contributing to variations in the visual interpretation of intrapartum cardiotocograph among healthcare professionals in the absence of adjunctive technologies.

View Article and Find Full Text PDF

Oxygen controls most metazoan metabolism, yet in mammals, tissue O levels vary widely. While extensive research has explored cellular responses to hypoxia, understanding how cells respond to physiologically high O levels remains uncertain. To address this problem, we investigated respiratory epithelia as their contact with air exposes them to some of the highest O levels in the body.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!