A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of ganciclovir in human plasma by ultra performance liquid chromatography-UV detection. | LitMetric

Objectives: Implement a sensitive UHPLC method for the assay of ganciclovir in human plasma.

Design And Methods: We developed and validated a chromatographic method coupled to ultraviolet detection for quantification of ganciclovir, with a short run time using a small volume of human plasma. Comparison of system performance was made with respect to analysis time, efficiency and sensitivity.

Results: Correlation coefficients (r) of the calibration curves ranged from 0.999744 to 0.999784. Within-day and between-day imprecision and inaccuracy, specificity and recovery were also evaluated for validation. The method was precise and accurate and the retention time was 0.7 min. The calibration curves were linear between 0.5 and 30 μg/mL. There was a good correlation between HPLC and UHPLC techniques.

Conclusions: We developed a method that is currently applied in a clinical study assessing GCV plasma concentration variability after ganciclovir and valganciclovir administration.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiochem.2011.12.014DOI Listing

Publication Analysis

Top Keywords

ganciclovir human
8
human plasma
8
calibration curves
8
determination ganciclovir
4
plasma ultra
4
ultra performance
4
performance liquid
4
liquid chromatography-uv
4
chromatography-uv detection
4
detection objectives
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!