Inter-rater reliability of sonographic measurements of the inferior vena cava.

J Emerg Med

Department of Emergency Medicine, Emergency Ultrasound Division, St. Luke's/Roosevelt Hospital Center, New York, New York 10025, USA.

Published: May 2012

Background: Bedside ultrasound is emerging as a useful tool in the assessment of intravascular volume status by examining measurements of the inferior vena cava (IVC). Many previous studies do not fully describe their scanning protocol.

Objectives: The objective of this study was to evaluate which of three commonly reported IVC scanning methods demonstrates the best inter-rater reliability.

Methods: Three physicians visualized the IVC in three common views and utilized M-mode to measure the maximal and minimal diameter during quiet respiration. Pairwise correlation coefficients were determined using Pearson product-moment correlation.

Results: The most reliable pair of measurements (inspiratory and expiratory) was found to be using the anterior midaxillary line longitudinal view with a Kappa value for both at 0.692.

Conclusion: Imaging with the anterior midaxillary longitudinal approach using the liver as an acoustic window provides the best inter-rater reliability when measuring the IVC. Our findings demonstrate that IVC measurements differ based on anatomic location.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jemermed.2011.05.095DOI Listing

Publication Analysis

Top Keywords

inter-rater reliability
8
measurements inferior
8
inferior vena
8
vena cava
8
best inter-rater
8
anterior midaxillary
8
midaxillary longitudinal
8
ivc
5
reliability sonographic
4
measurements
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!