1. Although, long half-life compounds appear to be more appropriate pharmacological indicators of compliance with treatment, short half-life markers or measurements of short half-life therapeutic drugs are frequently used. 2. We have compared the usefulness of low-dose phenobarbitone (a long half-life indicator), low dose isoniazid (a short half-life marker) and controlled release metoprolol (Metros) (a controlled release formulation of a short half-life 'therapeutic' drug) in seven volunteers with simulated partial (two thirds) compliance. 3. Detection of isoniazid metabolites in urine had an 83% sensitivity and 94% specificity for detecting ingestion within the previous 24 h and 100% sensitivity and 82% specificity for detecting ingestion within the past 6 h but gave no indication of the longer term pattern of compliance. 4. At 28 days (a time when steady-state would be obtained for all three drugs) phenobarbitone plasma levels were 70% (66-76%)--median and interquartile range--of the expected steady-state level if compliance had been complete. Corresponding figures for metoprolol were 82% (37-100%). 5. Measurement of phenobarbitone was much superior to isoniazid or metoprolol measurements in reflecting partial compliance over the previous 1 to 4 weeks.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1368147 | PMC |
http://dx.doi.org/10.1111/j.1365-2125.1990.tb03795.x | DOI Listing |