A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Single-step sandwich immunoreaction in a square glass capillary immobilizing capture and enzyme-linked antibodies for simplified enzyme-linked immunosorbent assay. | LitMetric

AI Article Synopsis

  • Developed a square glass capillary immunosensor for ELISA that simplifies the procedure and reduces reagent use by using covalently immobilized capture antibodies and physically adsorbed enzyme-linked antibodies.
  • The capture antibodies are attached using chemical treatments, while enzyme-linked antibodies are adsorbed with the help of polyethylene glycol.
  • The sensor allows for quick detection of human IgG with high precision and specificity, providing a quantitative analysis range of 10-5000 ng/mL anti-human IgG.

Article Abstract

To simplify the complicated operation steps and to minimize sample and reagent amounts for enzyme-linked immunosorbent assays (ELISA), we developed a square glass capillary immunosensor containing both covalently immobilized capture antibodies and physically adsorbed enzyme-linked antibodies. The immobilization of capture antibodies (anti-human IgG) was carried out by the treatment of 3-aminopropyltriethoxy silane, glutaraldehyde, and protein-A, followed by affinity capture of the antibody. In contrast, the enzyme-linked antibodies (alkaline phosphatase (ALP)-linked anti-human IgG) were physically adsorbed on the four corners of the capillary with the aid of polyethylene glycol (PEG) acting as a scaffold. A nanoliter volume of antigen (human IgG)-containing sample solution was introduced via capillary action. This addition resulted in the release and diffusion of ALP-linked anti-human IgG into the bulk solution. This event led to a 20-min single-step sandwich immunoreaction at the inner wall of capillary; the reaction was detected through the reaction with fluorescein diphosphate (FDP) which generated a fluorescent product, fluorescein. Using this technique, we obtained an intra-capillary precision with a coefficient of variation of 9.7%. In addition, the specificity study showed that the human IgG capillary immunosensor did not respond to rabbit IgG. Quantitative analysis was possible within the response range of 10 - 5000 ng mL(-1) anti-human IgG. This capillary immunosensor can act as a single analytical unit or can be integrated into a capillary array for multiple bioanalysis.

Download full-text PDF

Source
http://dx.doi.org/10.2116/analsci.28.51DOI Listing

Publication Analysis

Top Keywords

anti-human igg
16
enzyme-linked antibodies
12
capillary immunosensor
12
single-step sandwich
8
sandwich immunoreaction
8
square glass
8
capillary
8
glass capillary
8
enzyme-linked immunosorbent
8
capture antibodies
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!