The present study aimed to quantify the thickness of articular cartilage (Tc) in vitro using both conventional and real-time spatial compound B-mode ultrasonography (US) with a clinically used transducer and to evaluate the accuracy of measurement by comparing the results with values obtained microscopically. Femoral condyle samples were obtained from a 6-month-old pig and a 3-year-old pig. B-mode US images with conventional imaging and real-time spatial compound imaging (RTSCI) of osteochondral blocks were acquired. Tc determined using US (Tc-US) was measured from line data parallel to US beam direction acquired from B-mode images with an objective method for determining cartilage surface and bone-cartilage interfaces at the peak brightness values. Tc was also determined under microscopy (Tc-optical) using the corresponding points from US measurement. Tc-US was compared with Tc-optical to assess accuracy. Tc-US correlated significantly with Tc in both conventional imaging and RTSCI (r = 0.961, 0.976, respectively). Bland-Altman plots showed mean differences between Tc-optical and Tc-US were -0.0073 mm and 0.0139 mm with standard deviations of 0.171 mm and 0.131 mm for conventional imaging and RTSCI, respectively. Our results show that Tc-US measurement using B-mode US allows accurate measurement of Tc. Considering correlation coefficients between Tc-US and Tc-optical, RTSCI US may offer higher accuracy for measuring Tc than conventional methods when an objective tissue border determination algorithm is used, even though both showed good accuracy in our study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultrasmedbio.2011.11.012 | DOI Listing |
Bot Stud
January 2025
Crop Science Division, Taiwan Agricultural Research Institute, Ministry of Agriculture, Taichung, 413, Taiwan.
Background: Rice is a staple food for the global population. However, extreme weather events threaten the stability of the water supply for agriculture, posing a critical challenge to the stability of the food supply. The use of technology to assess the water status of rice plants enables the precise management of agricultural water resources.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Electrical Power, Adama Science and Technology University, Adama, 1888, Ethiopia.
Although the Transformer architecture has established itself as the industry standard for jobs involving natural language processing, it still has few uses in computer vision. In vision, attention is used in conjunction with convolutional networks or to replace individual convolutional network elements while preserving the overall network design. Differences between the two domains, such as significant variations in the scale of visual things and the higher granularity of pixels in images compared to words in the text, make it difficult to transfer Transformer from language to vision.
View Article and Find Full Text PDFSci Rep
January 2025
Refined Imaging LLC, Baton Rouge, LA, 70810, USA.
This study describes procedures for embedding digital information into additively manufactured components as well as procedures for readout and tensile testing. Embedded digital codes were printed inside ASTM E8/E8M dumbbells using Direct Metal Laser Melting (DMLS) with an EOS M290 printer. The codes were configured as either ellipsoids or prolate spheroids in patterns given by the Cantor dust fractal.
View Article and Find Full Text PDFAcad Radiol
January 2025
Department of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, St. Louis, MO 63110 (S.I., M.A.T., M.I., C.S., R.L., A.H., R.L.W., T.J.F.). Electronic address:
Rationale And Objective: Conventional positron emission tomography (PET) respiratory gating utilizes a fraction of acquired PET counts (i.e., optimal gate [OG]), whereas elastic motion correction with deblurring (EMCD) utilizes all PET counts to reconstruct motion-corrected images without increasing image noise.
View Article and Find Full Text PDFChin J Traumatol
January 2025
Department of Emergency Surgery and Orthopaedic Surgery, Qilu Hospital of Shandong University, Jinan, 250012, China. Electronic address:
Purpose: The fixation method commonly employed worldwide for treating unstable fractures of the posterior pelvic ring is the percutaneous iliosacral screw technique. However, prolonged operation time and frequent fluoroscopies result in surgical risks. This study aimed to investigate whether a new triangulation method could reduce operative and fluoroscopy times and increase the accuracy of screw placement.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!