A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Use of the reamer-irrigator-aspirator may reduce tumor dissemination during intramedullary fixation of malignancies. | LitMetric

Use of the reamer-irrigator-aspirator may reduce tumor dissemination during intramedullary fixation of malignancies.

Orthopedics

Department of Orthopaedic Surgery, Rush University Medical Center, 1725 W Harrison Ave, Ste 440, Chicago, IL 60612, USA.

Published: January 2012

Intramedullary nail fixation is the treatment of choice for impending and pathologic fractures secondary to metastatic cancer; however, this procedure has been shown to cause systemic embolization of intramedullary contents. This article reports the use of the reamer-irrigator-aspirator (RIA) (Synthes, Paoli, Pennsylvania) instead of a standard femoral reamer to decrease tumor intravasation during femoral intramedullary nail fixation for impending or pathologic fractures.Twenty-one consecutive patients indicated for fixation of malignant femoral lesions were treated with intramedullary nail placement. The RIA was used for canal preparation, and solid reamings were collected and submitted for analysis by a single pathologist. The volume of each specimen was recorded, and representative samples were examined histologically to determine their percent tumor content. These data were then used to estimate the volume of tumor retrieved by the RIA in each case. The mean volume of reamings collected by the RIA was 75.0 cc per case (range, 23.4-196.0 cc), and the mean tumor content was 24.8% (range, 1.0%-60.0%). The mean estimated volume of tumor retrieved in each case was 16.7 cc (range, 0.35-36.0 cc). In 2 cases, the tip of the RIA dissociated from the device intraoperatively but was retrieved without adverse consequence to the patient. Use of the RIA in cases of femoral intramedullary nail fixation for pathologic lesions or fractures effectively retrieves variable amounts of intramedullary contents, including tumor. By preventing the systemic dissemination of malignant cells, this technique may reduce the risk of distant metastases.

Download full-text PDF

Source
http://dx.doi.org/10.3928/01477447-20111122-09DOI Listing

Publication Analysis

Top Keywords

intramedullary nail
16
nail fixation
12
impending pathologic
8
intramedullary contents
8
femoral intramedullary
8
reamings collected
8
tumor content
8
volume tumor
8
tumor retrieved
8
tumor
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!