A new micro-computed tomography (μCT) image processing approach to estimate the loss of cement-bone interlock was developed using the concept that PMMA cement flows and cures around trabeculae during the total knee arthroplasty procedure. The initial mold shape of PMMA cement was used to estimate the amount of interdigitated bone at the time of implantation and following in vivo service using enbloc human postmortem retrievals. Laboratory prepared specimens, where there would be no biological bone resorption, were used as controls to validate the approach and estimate errors. The image processing technique consisted of identifying bone and cement from the μCT scan set, dilation of the cement to identify the cement cavity space, and Boolean operations to identify the different components of the interdigitated cement-bone regions. For laboratory prepared specimens, there were small errors in the estimated resorbed bone volume fraction (reBVfr=0.11 ± 0.09) and loss in contact area fraction (CAfr=0.06 ± 0.15). These values would be zero if there were no error in the method. For the postmortem specimens, the resorbed volume fraction (reBVfr=0.85 ± 0.16) was large, meaning that only 15% of the cement mold shape was still filled with bone. The loss of contact area fraction (CAfr=0.84 ± 0.17) was similarly large. This new approach provides a convenient method to visualize and quantify trabecular bone loss from interdigitated regions from postmortem retrievals. The technique also illustrates for the first time that there are dramatic changes in how bone is fixed to cement following in vivo service.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3278511 | PMC |
http://dx.doi.org/10.1016/j.jbiomech.2011.12.008 | DOI Listing |
J Mech Behav Biomed Mater
January 2025
Department of Mechanical Engineering, Boston University, Boston, MA 02215, USA; Center for Multiscale and Translational Mechanobiology, Boston University, Boston, MA 02215, USA; Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA.
Despite the broad agreement that bone stiffness is heavily dependent on the underlying bone density, there is no consensus on a unified relationship that applies to both cancellous and cortical compartments. Bone from the two compartments is generally assessed separately, and few mechanical test data are available for samples from the transitional regions between them. In this study, we present a data-driven framework integrating experimental testing and numerical modeling of the human lumbar vertebra through an energy balance criterion, to develop a unified density-modulus relationship across the entire vertebral body, without the necessity of differentiation between trabecular and cortical regions.
View Article and Find Full Text PDFAJR Am J Roentgenol
January 2025
Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA.
CT-based abdominal body composition measures have shown associations with important health outcomes. Artificial intelligence (AI) advances now allow deployment of tools that measure body composition in large patient populations. To assess associations of age, sex, and common systemic diseases on CT-based body composition measurements derived using a panel of fully automated AI tools in a population-level adult patient sample.
View Article and Find Full Text PDFJ Clin Med
December 2024
Swiss Visio Glaucoma Research Center, Montchoisi Clinic, 1006 Lausanne, Switzerland.
This study compares the long-term intraocular pressure (IOP)-lowering efficacy of standalone MINIject (iSTAR Medical, Belgium) suprachoroidal implantation and two iStent (Glaukos, CA, USA) trabecular bypass implantation using a systematic review and meta-analysis. Systematic review of standalone implantation of MINIject or iStent inject with at least 24 months of follow up. The mean and standard deviation of IOP and the number of IOP-lowering medications at baseline and at 24 months were extracted.
View Article and Find Full Text PDFBone
January 2025
Department of Research and Development, Schulthess Klinik, Lengghalde 2, 8008 Zürich, Switzerland. Electronic address:
Osteoarthritis (OA) is associated with sclerosis, a thickening of the subchondral bone plate, yet little is known about bone adaptations around full-thickness cartilage defects in severe knee OA, particularly beneath bone-on-bone wear grooves. This high-resolution micro-computed tomography (microCT) study aimed to quantify subchondral bone microstructure relative to cartilage defect location, distance from the joint space, and groove depth. Ten tibial plateaus with full-thickness cartilage defects were microCT-scanned to determine defect location and size.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
December 2024
Department of Mechanical Engineering, Western University, London, ON, Canada; The Roth|McFarlane Hand and Upper Limb Centre, St. Joseph's Hospital, London, ON, Canada; Department of Surgery, Western University, London, ON, Canada. Electronic address:
Introduction: Stress shielding remains a concern following total shoulder arthroplasty using press-fit short humeral stems. While the effect of alterations in implant geometry, positioning, and sizing on stress shielding have been investigated, the effects of coverage of the cortical boundary of the resection plane have not yet been fully explored. The purpose of this study was to quantify the effect of improved cortical coverage using elliptical vs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!