Background: In patients with ischemic heart failure undergoing cardiac resynchronization therapy (CRT) the underlying myocardial substrate at the left ventricle (LV) pacing site may affect CRT response. However, the effect of delivering the pacing stimulus remote, adjacent to or over LV transmural scar tissue (TST) identified by echocardiography is still unknown.
Methods: First, 35 patients with healed myocardial infarction (57 ± 11 years) were prospectically studied to demonstrate the capability of echocardiographic end-diastolic wall thickness (EDWT) to identify LV-TST as defined by delayed enhancement magnetic resonance imaging (DE-MRI). Subsequently, in 136 patients (65 ± 10 years) who underwent CRT, EDWT was retrospectively evaluated at baseline. The LV catheter placement was defined over, adjacent to and remote from TST if pacing was delivered at a scarred segment, at a site 1 segment adjacent to or remote from scarred segments. CRT response was defined as LV end-systolic volume (ESV) decrease by at least 10% after 6 months.
Results: A EDWT ≤ 5mm identified TST at DE-MRI with 92% sensitivity and 96% specificity. In the 76 CRT responders, less overall and posterolateral TST segments and more segments paced remote from TST areas were found. At the multivariate regression analysis, the number of TST segments and scar/pacing relationship showed a significant association with CRT response.
Conclusions: In addition to LV global scar burden, CRT response relates also to the myocardial substrate underlying pacing site as evaluated by standard echocardiography. This information may expand the role of echocardiography to guide pacing site avoiding pacing at TST areas.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijcard.2011.12.006 | DOI Listing |
Heart Rhythm
December 2024
School of Biomedical Engineering and Imaging Sciences, King's College London, UK.
Background: Electrocardiographic imaging (ECGi) is a non-invasive technique for ventricular tachycardia (VT) ablation planning. However, it is limited to reconstructing epicardial surface activation. In-silico pace mapping combines a personalized computational model with clinical electrocardiograms (ECGs) to generate a virtual 3D pace map.
View Article and Find Full Text PDFCureus
November 2024
Cardiology, Akita Cerebrospinal and Cardiovascular Center, Akita, JPN.
Background Ventricular septal pacing has long been performed using a stylet during pacemaker implantation, but with the availability of guiding catheters, His bundle pacing and left bundle branch area pacing have also been performed. However, it is not known to what extent the tip load of the ventricular lead differs when a guiding catheter is used compared with a stylet alone. In this study, the tip load was measured for different stylet stiffness and guiding catheter geometries at sites where His bundle pacing and left bundle branch area pacing were assumed.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
December 2024
Institute of Cardiovascular Sciences, University of Birmingham, Birmingham B15 2TT, UK.
Background Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a rare genetic disorder associated with an elevated risk of life-threatening arrhythmias and progressive ventricular impairment. Risk stratification is essential to prevent major adverse cardiac events (MACE). Our study aimed to investigate the incremental value of strain measured by two-dimensional speckle-tracking echocardiography in predicting MACE in ARVC patients compared to conventional echocardiographic parameters.
View Article and Find Full Text PDFJ Am Heart Assoc
December 2024
Graduate Program in Translational Biology Medicine and Health, Virginia Tech Roanoke VA USA.
Background: Previous studies suggest the relationship between activation time (AT) and action potential duration (APD) in the heart is dependent on electrotonic coupling, but this has not been directly tested. This study assessed whether acute changes in electrical coupling, or other determinants of conduction or repolarization, modulate APD heterogeneity.
Methods And Results: Langendorff-perfused guinea pig hearts were epicardially paced and optically mapped after treatment with the gap junction uncoupler carbenoxolone, ephaptic uncoupler mannitol, ephaptic enhancer dextran 2MDa, sodium channel inhibitor flecainide, or rapid component of the delayed rectifier potassium channel inhibitor E4031.
J Cardiovasc Electrophysiol
December 2024
Heart Center, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, location AMC, The Netherlands.
The extravascular implantable cardioverter-defibrillator (EV-ICD) was developed to overcome complications associated with transvenous leads while being able to deliver anti-tachycardia pacing (ATP). The lead is implanted in the substernal space, which makes extraction a cautious procedure. We present a case of a 51-year-old women with a successful EV-ICD extraction after a lead dwell time of 4 years, which is the longest reported.