Gait event detection on level ground and incline walking using a rate gyroscope.

Sensors (Basel)

Centre for Biomedical Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, Surrey, GU2 7XH, UK.

Published: July 2012

Gyroscopes have been proposed as sensors for ambulatory gait analysis and functional electrical stimulation systems. Accurate determination of the Initial Contact of the foot with the floor (IC) and the final contact or Foot Off (FO) on different terrains is important. This paper describes the evaluation of a gyroscope placed on the shank for determination of IC and FO in subjects walking outdoors on level ground, and up and down an incline. Performance was compared with a reference pressure measurement system. The mean difference between the gyroscope and the reference was less than -25 ms for IC and less than 75 ms for FO for all terrains. Detection success was over 98%. These results provide preliminary evidence supporting the use of the gyroscope for gait event detection on inclines as well as level walking.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3247727PMC
http://dx.doi.org/10.3390/s100605683DOI Listing

Publication Analysis

Top Keywords

gait event
8
event detection
8
level ground
8
ground incline
8
contact foot
8
detection level
4
incline walking
4
walking rate
4
gyroscope
4
rate gyroscope
4

Similar Publications

Portable monitoring devices based on Inertial Measurement Units (IMUs) have the potential to serve as quantitative assessments of human movement. This article proposes a new method to identify the optimal placements of the IMUs and quantify the smoothness of the gait. First, it identifies gait events: foot-strike (FS) and foot-off (FO).

View Article and Find Full Text PDF

A novel approach to assess coordination in people with transtibial amputations using continuous and event relative phase.

J Biomech

January 2025

UNC-NC State Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, 1407, Engineering Building III, 1840 Entrepreneur Drive, Raleigh, NC 27695, USA. Electronic address:

Continuous relative phase (CRP) quantifies coordination for cyclic motions as the difference in the phase portrait locations between its constituent coordinates and has been widely used in populations with neuromuscular impairments. Continuous analyses, like statistical parameter mapping (SPM), provide greater resolution than traditional techniques that first compress CRP across a section of the cycle to a single point, like mean average relative phase (MARP). However, both analyses neglect the effect of intermediate event timing (e.

View Article and Find Full Text PDF

A synchronized event-cue feedback loop integrating a 3D printed wearable flexible sensor-tactor platform.

Biosens Bioelectron

January 2025

Department of Physics, Virginia Commonwealth University, Richmond, VA, 23284, USA; Institute for Sustainable Energy and Environment, Virginia Commonwealth University, Richmond, VA, 23284, USA. Electronic address:

Wearable devices designed for the somatosensory system aim to provide event-cue feedback electronics and therapeutic stimulation to the peripheral nervous system. This prompts a neurological response that is relayed back to the central nervous system. Unlike virtual reality tools, these devices precisely target peripheral mechanoreceptors by administering specific stimuli.

View Article and Find Full Text PDF

Objective: Determining the optimal osteotomy length for patients with unilateral Crowe-IV developmental dysplasia of the hip undergoing subtrochanteric osteotomy remains challenging due to the significant variability in pelvic and spinal alignment. Incorrect osteotomy length, compounded by pelvic or spinal tilt, can adversely affect postoperative gait and long-term outcomes. Therefore, this study could introduce a method to calculate the osteotomy length for patients with unilateral Crowe-IV developmental dysplasia of the hip, correcting spinal and pelvic tilt, and improving patient gait.

View Article and Find Full Text PDF

Purpose: Silent brain infarcts, sometimes appearing as incidental lacunes in patients with unknown history of vascular event, are linked to dementia, gait disturbances and depression. We observed that some cavitating lacunes were only visible on b0-diffusion-weighted-imaging (b0-DWI: T2-weighted without diffusion gradients) when T2-weighted-spin-echo (T2-SE) was unavailable. We aimed to evaluate the additional value of b0-DWI in detecting cavitating lacunes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!