A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Curved cutter stapler for the application of bronchial sutures in anatomic pulmonary resections: the clinical experience of 139 cases. | LitMetric

Objectives: One of the fundamental steps in an anatomical pulmonary resection is the main and lobar bronchus suture. Nowadays, two different types of staplers are on the market: the linear TA stapler for open surgery (Tyco Healthcare Group LP, Norwalk, CT, USA), which is based on a 'guillotine' mechanism, sewing, but not cutting the bronchus, and the endoscopic linear stapler which both cuts and sews. This study aimed to fill the void in the use of an instrument used to staple and cut at the same time in 'open' thoracic surgery, eliminating the need for a scalpel: the curved cutter stapler (Contour Curved Cutter Stapler; Ethicon Endo-Surgery, Inc., Cincinnati, OH, USA).

Methods: Between May 2009 and March 2011, the Contour Curved Stapler (Ethicon) was used for the bronchus in 139 cases of non-small cell lung carcinoma (NSCLC)-29 females and 110 males ranging between 48 and 85 years (average 71.1)-and comprising 115 lobectomies (8 bilobectomies) and 24 pneumonectomies (8 on the right lung, 16 on the left lung).

Results: All patients underwent a bronchoscopic check-up 30 days after they were discharged: in all cases, the bronchial stump was clearly within normal limits. No cases of bronchopleural fistulas were observed in the 139 patients.

Conclusions: On the basis of this study, the curved cutter stapler showed to be a satisfactory device for securing the bronchus during an anatomic resection (whether lobar or main), in 'open' thoracic surgery. However, even though there were no cases of fistula, we consider that our data is still too limited to be statistically significant.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejcts/ezr090DOI Listing

Publication Analysis

Top Keywords

curved cutter
16
cutter stapler
16
139 cases
8
linear stapler
8
'open' thoracic
8
thoracic surgery
8
contour curved
8
stapler ethicon
8
stapler
7
curved
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!