The mechanical behavior of carbon nanotube (CNT)-based fibers and nanocomposites depends intimately on the shear interactions between adjacent tubes. We have applied an experimental-computational approach to investigate the shear interactions between adjacent CNTs within individual double-walled nanotube (DWNT) bundles. The force required to pull out an inner bundle of DWNTs from an outer shell of DWNTs was measured using in situ scanning electron microscopy methods. The normalized force per CNT-CNT interaction (1.7 ± 1.0 nN) was found to be considerably higher than molecular mechanics (MM)-based predictions for bare CNTs (0.3 nN). This MM result is similar to the force that results from exposure of newly formed CNT surfaces, indicating that the observed pullout force arises from factors beyond what arise from potential energy effects associated with bare CNTs. Through further theoretical considerations we show that the experimentally measured pullout force may include small contributions from carbonyl functional groups terminating the free ends of the CNTs, corrugation of the CNT-CNT interactions, and polygonization of the nanotubes due to their mutual interactions. In addition, surface functional groups, such as hydroxyl groups, that may exist between the nanotubes are found to play an unimportant role. All of these potential energy effects account for less than half of the ~1.7 nN force. However, partially pulled-out inner bundles are found not to pull back into the outer shell after the outer shell is broken, suggesting that dissipation is responsible for more than half of the pullout force. The sum of force contributions from potential energy and dissipation effects are found to agree with the experimental pullout force within the experimental error.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/nl203686d | DOI Listing |
Nanomaterials (Basel)
January 2025
Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Hong Kong.
Helical carbon nanotubes (HCNTs) with different geometrical properties were constructed and incorporated into nanocomposites for the investigation of the anti-crack mechanism. The interfacial mechanical properties of the nanocomposites reinforced with straight carbon nanotubes and various types of HCNTs were investigated through the pullout of HCNTs in the crack propagation using molecular dynamics (MD). The results show that the pullout force of HCNTs is much higher than that of CNTs because the physical interlock between HCNTs and matrices is much stronger than the van der Waals (vdW) interactions between CNTs and matrices.
View Article and Find Full Text PDFSci Rep
January 2025
Departmant of Orthopedics and Traumatology, Liv Ulus Hospital, Istanbul, Turkey.
Locking plates have a rapidly growing process especially in the past decades and results are satisfactory especially in the osteoporotic bones compared to non-locking compression plates. There are many forms of failure in the fracture fixation of locking plates, and screw pull-out is one of the main failure reasons. In this study, we aim to investigate pull-out failure in locking plates using locking spongious screws.
View Article and Find Full Text PDFBiomed Tech (Berl)
January 2025
Oral Technology, University of Bonn, Bonn, Germany.
Objectives: The aim of the present study was to investigate, whether polyetherketoneketone (PEKK) secondary crowns could be considered as alternative to gold standard in terms of their physical properties and manufacturing costs.
Methods: An upper jaw model with six implants was used. Frameworks with either 6 PEKK- or 6 electroplated secondary crowns were cemented in a wear simulator.
J Orthop Surg Res
January 2025
Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taoyuan, Taiwan.
Objective: Combining oblique lumbar interbody fusion (OLIF) with posterior pedicle screw fixation (PPSF) has been proposed to reduce cage subsidence, especially in osteoporotic spines. Recently, anterolateral screw-rod fixation has gained interest as it allows direct pathology observation and avoids a posterior approach. However, controversies exist between anterolateral screw fixation systems and traditional PPSF due to variations in osteoporotic vertebral mineral density, screw fixation positions, and fixation methods (bicortical vs.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC 29208, USA.
The mechanical properties of lignin, an aromatic heteropolymer constituting 20-30% plant biomass, are important to the fabrication and processing of lignin-based sustainable polymeric materials. In this study, atomistic simulations are performed to provide microscopic insights into the mechanics of lignin. Representative samples of miscanthus, spruce, and birch lignin are studied.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!