Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A fast and selective ultraperformance liquid chromatographic-tandem mass spectrometric method was developed and validated for the simultaneous quantification of amitriptyline, citalopram, clomipramine, desipramine, desmethylcitalopram, desmethylclomipramine, desmethyldosulepin, desmethyldoxepin, desmethylfluoxetine, desmethylvenlafaxine, didesmethylcitalopram, dosulepin, doxepin, duloxetine, fluoxetine, fluvoxamine, imipramine, maprotiline, mianserin, mirtazapine, moclobemide, nortriptyline, paroxetine, reboxetine, sertraline, trazodone, and venlafaxine in 100 μL of plasma. After liquid-liquid extraction with 1-chlorobutane, analytes were separated on a BEH (Ethylene Bridged Hybrid) C18 analytical column with gradient elution. The compounds were ionized and detected over 7-minute analysis time by electrospray ionization tandem mass spectrometry with multiple reaction monitoring. Limits of quantification and limits of detection ranged from 2.5 to 10 ng/mL and 0.2 to 10 ng/mL, respectively. Intra- and interassay imprecision were lower than 15% for all the compounds except for mirtazapine, moclobemide, and desmethylclomipramine [relative standard deviation (RSD) < 20%], and the bias of the assay was lower than 15% for all the compounds except for fluvoxamine (bias < 20.5%), evaluated with 5 commercial quality control and 3 "in-house" quality control. The extraction was found to be reproducible (RSD < 16%) (except for duloxetine RSD 21.9%) and with recoveries varying from 59% to 86%. Furthermore, the stability studies demonstrated that the processed samples were stable in the autosampler for 24 hours for all the compounds. The method was successfully applied to the analysis of authentic samples from forensic toxicology cases and external quality control assays from the Society of Toxicology and Forensic Chemistry (GTFCh). The method was completely validated and can be of interest to clinical and forensic laboratories.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/FTD.0b013e31823bf0fd | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!