BACKGROUND: Functional outcome in surgical treatment of Neer three- and four-part proximal humerus fractures (PHF) varies greatly and depends on multiple parameters. Important parameters are the amount and direction of displacement and the necessary reduction of fragments during surgery. These are patient-specific parameters and are difficult to determine using traditional modalities such as radiographs and computed tomography (CT). METHODS: A 58-year-old female patient was reported in the emergency department with a three-part PHF. CT scan images showed that the humeral shaft was medialised and internally rotated, but with a marginally displaced greater tuberosity fragment. Using a bone-determined range of motion (ROM) simulation system, we analysed the CT scan and calculated the required correction needed to prevent post-operative impingement. The fracture was reduced and stabilised by a locking plate, realigning the medialised and internally rotated humeral shaft. The post-operative bone-determined ROM was determined using a post-operative CT scan and the motion simulation system. RESULTS: ROM limitations due to bony impingement visible in the simulations of the pre-operative CT scan had mostly disappeared in the simulations of the post-operative CT scan. Twelve weeks post-surgery the patient has regained close to 80% of her ROM. CONCLUSIONS: This case demonstrates the applicability of a new diagnostic tool that can be used to identify bony impingement and helps in making the decision for conservative or surgical treatment of a PHF. The simulation of post-trauma function was indicative of functional outcome. This supports our claim that the system may be used to facilitate the treatment decision regarding PHF.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3228961PMC
http://dx.doi.org/10.1007/s12570-011-0080-8DOI Listing

Publication Analysis

Top Keywords

range motion
8
proximal humerus
8
humerus fractures
8
functional outcome
8
surgical treatment
8
humeral shaft
8
medialised internally
8
internally rotated
8
simulation system
8
post-operative scan
8

Similar Publications

Long-term follow-up study of Kudo Type-5 elbow prosthesis in patients with rheumatoid arthritis: minimum 10-year clinical outcomes.

J Shoulder Elbow Surg

December 2024

Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan. Electronic address:

Objectives: Rheumatoid arthritis often leads to debilitating damage in the elbow joint, which may require total elbow arthroplasty (TEA). The Kudo TEA is one of the unlinked type prostheses with reportedly favorable outcomes. However, there is limited information available regarding its long-term performance.

View Article and Find Full Text PDF

Sling is Not-Inferior to Brace Immobilization Following Arthroscopic Rotator Cuff Repair: A Randomized Controlled Trial.

Arthroscopy

December 2024

Orthopaedic and Traumatology Unit, Ospedale Regionale di Lugano, EOC, 6900, Lugano, Switzerland; Faculty of Biomedical Sciences, Università della Svizzera Italiana, Via Buffi 13, 6900, Lugano, Switzerland.

Purpose: The aim of this study was to compare the safety and efficacy of immobilizing the upper limb with a brace versus a less-constrained sling in the rehabilitation after arthroscopic rotator cuff repair (ARCR), by documenting clinical and radiological results.

Methods: ARCR was performed in 110 patients (54.9±8.

View Article and Find Full Text PDF

Assessment of varus thrust using inertial measurement units.

Clin Biomech (Bristol)

December 2024

Department of Kinesiology and Applied Physiology, University of Delaware, Newark, DE, USA. Electronic address:

Background: Varus thrust is common in those with knee osteoarthritis. Varus thrust is traditionally identified with visual analysis or motion capture, methods that are either dichotomous or limited to the laboratory setting. Inertial measurement unit data has been found to correlate with motion capture measures of varus thrust in those with severe knee osteoarthritis, allowing for a quantitative and accessible way of measuring varus thrust.

View Article and Find Full Text PDF

Background: Total hip arthroplasty is the preferred treatment for advanced hip osteoarthritis, yet complications like hip dislocation (0.2 %-10 %) persist due to factors such as implant design, positioning, surgical technique, and patient-specific conditions. Impingement between prosthetic components or the acetabulum and proximal femur is a primary cause of instability.

View Article and Find Full Text PDF

Background: This study aims to investigate the effect of a newly developed virtual reality task-oriented training (VR-TOT) video game on upper extremity fine motor function compared with conventional occupational therapy through leap motion in children with spastic hemiplegic cerebral palsy (CP).

Methods: In this double-blind randomized clinical trial, 30 children with spastic hemiplegic CP aged six to 10 years were included and randomly allocated into two groups. During six weeks, 15 patients in the intervention group received VR_TOT-based video game in addition to conventional occupational therapy, whereas 15 patients in the control group received only conventional occupational therapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!