Effect of sample tilt on PEEM resolution.

Ultramicroscopy

Institute of Scientific Instruments AS CR, Královopolská 147, 61264 Brno, Czech Republic.

Published: August 2012

In electron microscopy design, the systems are usually assumed to be perfectly aligned or that possible small imperfections can be eliminated by simple multipole correctors (centering deflectors, stigmators) without loss of resolution. However, in some cases, like in the cathode lens between the sample and the objective lens in the photoemission electron microscope, even a small imperfection can impair the resolution significantly. Because of the strong field between the sample and the objective lens, even a small tilt of the sample generates a parasitic dipole field, which decreases resolution and causes image deformations. We present a simulation of the influence of a small sample tilt on the system resolution based on modern computational methods that enable simulation of the whole system including the parasitic fields, proper setting of centering deflectors and stigmators. The resolution is determined by simulating the point spread function and finding the size of its significant part. The procedure is shown on realistic data from the literature. We found out that the resolution becomes worse mainly in the direction of the parasitic dipole field.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2011.11.011DOI Listing

Publication Analysis

Top Keywords

sample tilt
8
centering deflectors
8
deflectors stigmators
8
sample objective
8
objective lens
8
parasitic dipole
8
dipole field
8
resolution
7
sample
5
tilt peem
4

Similar Publications

Background: Oncolytic viruses (OVs) are promising immunotherapeutics to treat immunologically cold tumors. However, research on the mechanism of action of OVs in humans and clinically relevant biomarkers is still sparse. To induce strong T-cell responses against solid tumors, TILT-123 (Ad5/3-E2F-d24-hTNFa-IRES-hIL2, igrelimogene litadenorepvec) was developed.

View Article and Find Full Text PDF

Protocol for estimating the contrast transfer function and absolute tilt angle offset for cryo-electron tomography using CTFMeasure.

STAR Protoc

January 2025

Key Laboratory for Protein Sciences of Ministry of Education, School of Life Sciences, Tsinghua University, Beijing 100084, China; State Key Laboratory of Membrane Biology, School of Life Sciences, Tsinghua University, Beijing 100084, China; Tsinghua-Peking Joint Center for Life Sciences, Beijing 100084, China; Beijing Frontier Research Center for Biological Structure, Beijing 100084, China; School of Life Sciences, Tsinghua University, Beijing 100084, China. Electronic address:

Contrast transfer function (CTF) estimation is essential to the data processing workflow of cryo-electron tomography (cryoET). Here, we present a protocol for CTF estimation of the cryoET tilt series with CTFMeasure. CTFMeasure can estimate the CTF parameters together with the absolute tilt angle offset of the sample.

View Article and Find Full Text PDF

Objective: Determining the optimal osteotomy length for patients with unilateral Crowe-IV developmental dysplasia of the hip undergoing subtrochanteric osteotomy remains challenging due to the significant variability in pelvic and spinal alignment. Incorrect osteotomy length, compounded by pelvic or spinal tilt, can adversely affect postoperative gait and long-term outcomes. Therefore, this study could introduce a method to calculate the osteotomy length for patients with unilateral Crowe-IV developmental dysplasia of the hip, correcting spinal and pelvic tilt, and improving patient gait.

View Article and Find Full Text PDF

Efficient Data Sampling Scheme to Reduce Acquisition Time in Statistical ALCHEMI.

Microscopy (Oxf)

January 2025

Department of Materials Physics, Graduate School of Engineering, Nagoya University, Chikusa-ku, Nagoya 464-8603, Japan.

The distribution of dopants in host crystals significantly influences the chemical and electronic properties of materials. Therefore, determining this distribution is crucial for optimizing material performance. The previously developed statistical ALCHEMI (St-ALCHEMI), an extension of the atom-location by channeling-enhanced microanalysis (ALCHEMI) technique, utilizes variations in electron channeling based on the beam direction relative to the crystal orientation.

View Article and Find Full Text PDF

Objectives: This study aims to assess the alterations in condylar positioning in adult skeletal Class I patients with unilateral posterior crossbite after microimplant-assisted rapid palatal expansion (MARPE) treatment.

Methods: This retrospective study involving 30 participants (10 males, 20 females) average age 22.9 ± 4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!