Context: Introduction of highly sensitive troponin assays into clinical practice has substantially improved the evaluation of patients with chest pain.

Objective: To evaluate the diagnostic performance of a highly sensitive troponin I (hsTnI) assay compared with a contemporary troponin I (cTnI) assay and their serial changes in the diagnosis of acute myocardial infarction (AMI).

Design, Setting, And Patients: A total of 1818 patients with suspected acute coronary syndrome were consecutively enrolled at the chest pain units of the University Heart Center Hamburg, the University Medical Center Mainz, and the Federal Armed Forces Hospital Koblenz, all in Germany, from 2007 to 2008. Twelve biomarkers including hsTnI (level of detection, 3.4 pg/mL) and cTnI (level of detection, 10 pg/mL) were measured on admission and after 3 and 6 hours.

Main Outcome Measures: Diagnostic performance for AMI of baseline and serial changes in hsTnI and cTnI results at 3 hours after admission to the emergency department.

Results: Of the 1818 patients, 413 (22.7%) were diagnosed as having AMI. For discrimination of AMI, the area under the receiver operating characteristic (ROC) curve was 0.96 (95% CI, 0.95-0.97) for hsTnI on admission and 0.92 (95% CI, 0.90-0.94) for cTnI on admission. Both were superior to the other evaluated diagnostic biomarkers. The use of hsTnI at admission (with the diagnostic cutoff value at the 99th percentile of 30 pg/mL) had a sensitivity of 82.3% and a negative predictive value (for ruling out AMI) of 94.7%. The use of cTnI (with the diagnostic cutoff value at the 99th percentile of 32 pg/mL) at admission had a sensitivity of 79.4% and a negative predictive value of 94.0%. Using levels obtained at 3 hours after admission, the sensitivity was 98.2% and the negative predictive value was 99.4% for both hsTnI and cTnI assays. Combining the 99th percentile cutoff at admission with the serial change in troponin concentration within 3 hours, the positive predictive value (for ruling in AMI) for hsTnI increased from 75.1% at admission to 95.8% after 3 hours, and for cTnI increased from 80.9% at admission to 96.1% after 3 hours.

Conclusions: Among patients with suspected acute coronary syndrome, hsTnI or cTnI determination 3 hours after admission may facilitate early rule-out of AMI. A serial change in hsTnI or cTnI levels from admission (using the 99th percentile diagnostic cutoff value) to 3 hours after admission may facilitate an early diagnosis of AMI.

Download full-text PDF

Source
http://dx.doi.org/10.1001/jama.2011.1896DOI Listing

Publication Analysis

Top Keywords

hstni ctni
16
hours admission
16
99th percentile
16
admission
13
serial changes
12
highly sensitive
12
sensitive troponin
12
diagnostic cutoff
12
negative predictive
12
hstni
9

Similar Publications

Background: Switching from a conventional to a high-sensitivity cardiac troponin (hs-cTn) assay enables detection of smaller amounts of myocardial damage, but the clinical benefit is unclear. We investigated whether switching to a hs-cTnI assay with a sex-specific 99th centile diagnostic threshold was associated with lower 1-year death or new myocardial infarction (MI) in patients with suspected acute coronary syndrome (ACS).

Methods: This pre-post study included nine tertiary hospitals in Australia.

View Article and Find Full Text PDF
Article Synopsis
  • This study assessed the diagnostic value and cost-effectiveness of using the i-STAT® point-of-care analyzer for measuring cardiac troponin I (cTnI) levels in dogs and cats suspected of heart disease.
  • A total of 240 animals (120 dogs and 120 cats) were examined, comparing the results from i-STAT® with two established laboratory assays (IMMULITE® 2000 and ACCESS®).
  • While the i-STAT® method effectively differentiated normal and elevated cTnI levels, caution is advised when interpreting high cTnI values, as there is a notable bias compared to traditional assays, particularly important for diagnosing severe cardiac conditions like myocarditis or acute ischemia.
View Article and Find Full Text PDF

Background: The most frequent lesion in the blood vessels feeding the myocardium is vascular stenosis, a condition that develops slowly but can prove to be deadly in a long run. Non-invasive biomarkers could play a significant role in timely diagnosis, detection and management for vascular stenosis events associated with cardiovascular disorders.

Aims: The study aimed to investigate high sensitivity troponin I (hs-TnI), cardiac troponin I (c-TnI) and high sensitivity C-reactive protein (hs-CRP) that may be used solely or in combination in detecting the extent of vascular stenosis in CVD patients.

View Article and Find Full Text PDF

Exercise-induced cardiac troponin elevations and cardiac ventricular dysfunction assessed by tissue Doppler echocardiography and speckle tracking among non-elite runners in Beijing marathon.

J Sci Med Sport

August 2024

Department of Cardiology, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, PR China; Peking University Fifth School of Clinical Medicine, Beijing, PR China; Chinese Academy of Medical Sciences and Peking Union Medical College, PR China; College of Life Science, University of Chinese Academy of Sciences, Beijing, China. Electronic address:

Article Synopsis
  • The study aimed to find out what factors affect changes in cardiac troponin levels after exercise in non-elite runners during the Beijing 2022 marathon, focusing on cardiac function measured by advanced ultrasound techniques.
  • A total of 33 participants underwent echocardiographic assessments and blood tests before, immediately after, and two weeks post-marathon, showing significant increases in cardiac troponin levels following the race.
  • Key findings indicated that baseline troponin levels and weekly training were important predictors of post-marathon troponin increases, with notable changes in cardiac function that returned to normal within two weeks.
View Article and Find Full Text PDF

Trends in high-sensitivity cardiac troponin I (hs-cTnI) after lung transplant (LT) and its clinical value are not well stablished. This study aimed to determine kinetics of hs-cTnI after LT, factors impacting hs-cTnI and clinical outcomes. LT recipients from 2015 to 2017 at Toronto General Hospital were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!