Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This study evaluated the effects of thermocycling and different light sources on the bond strength of metallic brackets to bovine tooth enamel using an adhesive resin. Bovine teeth were etched with 35% phosphoric acid gel for 20 s. After application of primer, metallic brackets were bonded to the buccal surface using Transbond XT, forming 8 groups (n = 20), depending on the light source used for photoactivation (AccuCure 3000 argon laser--20 s, Apollo 95E plasma arc--12 s, UltraLume 5 LED--40 s and XL2500 halogen light--40 s) and experimental conditions without (Groups 1 to 4) or with thermocycling (Groups 5 to 8). Shear bond testing was carried out after 24 h of distilled water storage (Groups 1 to 4) or storage and thermocycling in distilled water (groups 5 to 8; 1,500 cycles--5°/55 °C). Data were subjected to two-way ANOVA and Tukey's test (α = 0.05). The Adhesive Remnant Index (ARI) was evaluated at ×8 magnification. No significant differences (p>0.05) in bond strength were found when the conditions without and with thermocycling were compared for any of the light sources. No significant differences (p>0.05) in bond strength were found among the light sources, irrespective of performing or not thermocycling. There was a predominance of ARI scores 1 in all groups. In conclusion, light sources and thermocycling had no influence on the bond strength of brackets to bovine enamel.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/s0103-64402011000600008 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!