Objective: We sought to determine the value of preoperative left ventricular function and cardiopulmonary bypass parameters in the prediction of left ventricular assist device implantation after repair of anomalous left coronary artery from the pulmonary artery.

Methods: Multivariate logistic regression was performed to identify a predictive model for postrepair left ventricular assist device implantation using the records of 27 patients who underwent direct aortic implantation of anomalous left coronary artery from the pulmonary artery from 1994 to 2011.

Results: Seven patients required left ventricular assist device implantation. Patients in group 1 (n = 20) were successfully weaned from cardiopulmonary bypass. Patients in group 2 (n = 7) required left ventricular assist device as a bridge to recovery. The 2 groups were similar in age, weight, and body surface area. Six of the 7 patients (85.7%) who required left ventricular assist device survived to hospital discharge. Hospital mortality was 3.7%. In the univariate model, fractional shortening, ejection fraction, and aortic crossclamp time were significantly associated with left ventricular assist device implantation (P = .026, .035, .031, respectively). In the multivariate analysis, the aortic crossclamp time was the only significant independent predictor of left ventricular assist device implantation. Aortic crossclamp time and fractional shortening together accounted for 80.9% (P < .001) of the variability in left ventricular assist device implantation and constituted the best predictive model: All patients requiring postrepair left ventricular assist device implantation had a fractional shortening less than 20% and an aortic crossclamp time greater than 56 minutes.

Conclusions: The fractional shortening and aortic crossclamp time together predict 80.9% of the variability in postrepair left ventricular assist device implantation after repair of anomalous left coronary artery from the pulmonary artery. When preoperative left ventricular dysfunction is severe (fractional shortening < 20%), an aortic crossclamp time greater than 56 minutes is associated with a substantial risk of left ventricular assist device implantation after repair of anomalous left coronary artery from the pulmonary artery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2011.12.004DOI Listing

Publication Analysis

Top Keywords

left ventricular
56
ventricular assist
48
assist device
48
device implantation
40
aortic crossclamp
24
crossclamp time
24
anomalous left
20
left coronary
20
coronary artery
20
artery pulmonary
20

Similar Publications

: The utilization of intra-aortic balloon pump (IABP) and Impella has been suggested as means of left ventricular unloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO) patients. This study aimed to assess the local hemodynamic alterations in VA-ECMO patients through simulation analyses. : In this study, a 0D-3D multiscale model was developed, wherein resistance conditions were employed to define the flow-pressure relationship.

View Article and Find Full Text PDF

Objectives: This fourth report aimed to provide insights into patient characteristics, outcomes, and standardized outcome ratios of patients implanted with durable Mechanical Circulatory Support across participating centers in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) registry.

Methods: All registered patients receiving durable mechanical circulatory support up to August 2024 were included. Expected number of events were predicted using penalized logistic regression.

View Article and Find Full Text PDF

Aims: How the underlying etiology and pathophysiology of left ventricular (LV) hypertrophy affects LA remodeling and function remains unexplored. The present study aims to investigate the influence of various hypertrophic phenotypes on LA remodeling and function.

Methods And Results: Patients with LV hypertrophy who underwent cardiac magnetic resonance (CMR) were compared to a control group.

View Article and Find Full Text PDF

A Novel Staging System of Cardiac Damage in Aortic Stenosis based on Multi-Chamber Myocardial Deformation.

Eur Heart J Cardiovasc Imaging

January 2025

Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.

Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).

Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).

View Article and Find Full Text PDF

Thalamic hemorrhage is a type of intracerebral hemorrhage with high disability and mortality rates. Because of its deep bleeding location, irregular shape of the hematoma, and compression of the third ventricle, it is not suitable for craniotomy. This paper reports a case of a 63-year-old male patient who sought medical attention for left-sided basal ganglia and thalamus hemorrhage that broke into the ventricles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!