Objective: To radiographically evaluate periprosthetic femoral bone contrast and assess alignment of the prosthetic stem after uncemented and cemented total hip replacement (THR).
Study Design: Prospective clinical study.
Animals: Dogs (n = 15).
Methods: Dogs were classified into uncemented (n = 8) and cemented (n = 7) THR groups. Radiographs were analyzed using image processing software to evaluate femoral bone contrast (gray scale value, GV) for each and combined modified Gruen zone(s) immediately and 4 months after THR. Modified Gruen zones were classified into 5 zones to analyze retrospectively the regional radiographic GV of the femur around uncemented and cemented prosthetic stem. Alignment of prosthetic stem was assessed immediately and 4 months postoperatively. Variables were compared by use of 2-tailed t-test, with P < .05 considered significant.
Results: Zone 1 showed significant decrease in the mean bone GV 4 months after uncemented THR. No differences in zones 1-5 after 4 months of cemented THR. Combined zones showed significant decrease in overall mean bone GV 4 months after uncemented THR. No changes were observed 4 months after cemented THR. Number of limbs with varus-aligned femoral stem markedly increased after 4 months of uncemented THR.
Conclusions: Regional bone contrast and prosthetic stem alignment vary with the design of THR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1532-950X.2011.00931.x | DOI Listing |
Zhonghua Yan Ke Za Zhi
January 2025
Shenzhen Eye Hospital, Jinan University, Shenzhen Institute of Eye Disease Control, Shenzhen518040, China.
Retinitis pigmentosa (RP) is a group of inherited retinal diseases characterized by progressive loss of photoreceptor cells and retinal pigment epithelium function. Its treatment has long been a focus and challenge in ophthalmic research. Despite advances in therapies such as stem cell transplantation, gene therapy, and retinal prosthetic implants, many difficulties remain.
View Article and Find Full Text PDFRev Bras Ortop (Sao Paulo)
November 2024
Departamento de Ortopedia, Fortis Hospital, Mohali, Punjab, Índia.
Ophthalmic Plast Reconstr Surg
January 2025
Hariram Motumal Nasta & Renu Hariram Nasta Ophthalmic Plastic Surgery Services.
Purpose: To report the long-term surgical outcomes of acquired ankyloblepharon correction using mucous membrane graft.
Methods: Five eyes of 4 patients (median age, 19 years) with acquired ankyloblepharon were managed using eyelid splitting and mucous membrane graft anchored to the recti muscles on the bulbar surface in the respective quadrant and onto the bare tarsal surface. Outcome measures include a change in the palpebral fissure width, ability to fit scleral contact lenses, visual acuity, and cosmesis.
Tissue Cell
December 2024
Stem Cells Technology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran; Department of Natural Sciences, West Kazakhstan Marat Ospanov Medical University, Aktobe, Kazakhstan. Electronic address:
Addressing mandibular defects poses a significant challenge in maxillofacial surgery. Recent advancements have led to the development of various biomimetic composite scaffolds aimed at facilitating mandibular defect reconstruction. This study aimed to assess the regenerative potential of a novel composite scaffold consisting of polylactic acid (PLA), hydroxyapatite nanoparticles (n-HA), gelatin, hesperidin, and human dental pulp stem cells (DPSCs) in a rat model of mandibular bone defect.
View Article and Find Full Text PDFBiomed Mater
December 2024
Department of Chemical Engineering, Indian Institute of Technology - Bombay, Powai, Mumbai 400 076, Mumbai, Maharastra, 400076, INDIA.
Mechanical non-conformance of conventionally used transvaginal non-degradable meshes has led to complications like organ perforation, dyspareunia caused by mesh stiffness, and stress shielding. In this study, we have solved the dire need of mimicking the mechanical properties of vaginal wall by designing and developing a soft and elastic mesh made of polycaprolactone (PCL), citric acid modified polyethylene glycol (PEGC) and zinc oxide (ZnO) prepared through electrospinning and is tested in-vitro and in-vivo. Mesh containing 90:10:0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!