A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In vivo response to electrochemically aligned collagen bioscaffolds. | LitMetric

In vivo response to electrochemically aligned collagen bioscaffolds.

J Biomed Mater Res B Appl Biomater

Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907-2032.

Published: February 2012

Collagen-based biomaterials are a viable option for tendon reconstruction and repair. However, the weak mechanical strength of collagen constructs is a major limitation. We have previously reported a novel methodology to form highly oriented electrochemically aligned collagen (ELAC) threads with mechanical properties converging on those of the natural tendon. In this study, we assessed the in vivo response of rabbit patellar tendon (PT) to braided ELAC bioscaffolds. Rabbit PTs were incised longitudinally and the ELAC bioscaffold was inlaid in one limb along the length of the tendon. The contralateral limb served as the sham-operated control. Rabbits were euthanized at 4 or 8 months postoperatively. High-resolution radiographs revealed the absence of ectopic bone formation around the bioscaffolds. Four months post-implantation, the histological sections showed that the ELAC bioscaffold underwent limited degradation and was associated with a low-grade granulomatous inflammation. Additionally, quantitative histology revealed that the cross-sectional areas of PTs with the ELAC bioscaffold were 29% larger compared with the controls. Furthermore, ELAC-treated PTs were significantly stiffer compared with the controls. The volume fraction of the tendon fascicle increased in the ELAC-treated PT compared with the controls. By 8 months, the ELAC bioscaffold was mostly absorbed and the enlargement in the area of tendons with implants subsided along with the resolution of the granulomatous inflammation. We conclude that ELAC is biocompatible and biodegradable and has the potential to be used as a biomaterial for tendon tissue engineering applications.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.31962DOI Listing

Publication Analysis

Top Keywords

elac bioscaffold
16
compared controls
12
vivo response
8
electrochemically aligned
8
aligned collagen
8
granulomatous inflammation
8
elac
7
tendon
6
response electrochemically
4
collagen bioscaffolds
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!