Objective: To determine the accuracy of computed tomography (CT) dynamic stress myocardial perfusion imaging to estimate myocardial blood flow (MBF) in a porcine animal model with variable degrees of induced coronary artery stenosis in comparison with microsphere-derived MBF.
Methods And Materials: Seven domestic pigs (36 ± 4 kg) received stents (confirmed 3.0 mm diameter) in the left anterior descending coronary artery distal to first diagonal branch. A balloon catheter was placed within the stent and inflated to various degrees to obtain a defined luminal narrowing (50% and 75% diameter stenosis) as confirmed by intra-arterial flow wire measurement. All models underwent adenosine-mediated (140 μg/kg/min) dynamic stress and rest myocardial perfusion CT imaging using a dual-source CT scanner (shuttle-mode with 100 kV/300 mAs, 20 mL iopromide) with prospective acquisitions every second heartbeat for 30 seconds. CT-estimated MBF (MBFCT) was calculated using a model-based parametric deconvolution method and correlated to that of fluorescent microspheres (MBFmic) injected at each perfusion state.
Results: All study procedures were performed without complications, and all animals completed the study protocol. Among 448 myocardial segments, 31 (7%) were considered nonevaluable because of motion artifacts. With stress, MBFCT increased significantly (1.10 ± 0.25 vs. 0.80 ± 0.28 mL/g/min, P < 0.001; at stress and rest, respectively) in all myocardial segments and correlated with MBFmic (r = 0.67, P < 0.001). MBFCT overestimated MBFmic, independently of adenosine-stress and degree of coronary stenosis (β = 2.3, 95% confidence interval: 1.81-2.79 mL/g/min, P < 0.001). Although there were no differences in MBFCT between 50% and 75% coronary stenosis at rest (0.01 ± 0.08 mL/g/min, P = 0.86), MBFCT was significantly lower at 75% than at 50% under stress conditions (0.53 ± 0.19 vs. 0.71 ± 0.24 mL/g/min, P = 0.002).
Conclusions: CT-derived MBF measurements at rest and stress with varying degrees of coronary stenosis show a valid difference but an underestimated correlation with microsphere-derived MBF in a porcine animal model.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/RLI.0b013e31823fd42b | DOI Listing |
Int J Mol Sci
December 2024
Institute of Pharmacology and Clinical Pharmacy, Faculty of Pharmacy, Biochemical and Pharmacological Center (BPC) Marburg, University of Marburg, 35032 Marburg, Germany.
encodes the α1c subunit of the L-type Ca channel, Cav1.2. Ventricular myocytes from haploinsufficient () rats exhibited reduced expression of Cav1.
View Article and Find Full Text PDFMedicina (Kaunas)
December 2024
Department Cardiovascular Surgery, Gazi University Faculty of Medicine, Ankara 06560, Turkey.
Ischemia-reperfusion (I/R) injury is a process in which impaired perfusion is restored by restoring blood flow and tissue recirculation. Nanomedicine uses cutting-edge technologies that emerge from interdisciplinary influences. In the literature, there are very few in vivo and in vitro studies on how cerium oxide (CeO) affects systemic anti-inflammatory response and inflammation.
View Article and Find Full Text PDFJ Clin Med
December 2024
2nd Department of Internal Medicine Research Unit and Diabetes Centre, Attikon Hospital, Medical School, National and Kapodistrian University of Athens, Rimini 1 Str., Chaidari, 12462 Athens, Greece.
: The association between diabetic nephropathy and arterial elasticity and endothelial function is well established. In this study, we compared the effect of the combination of dulaglutide and dapagliflozin versus DPP-4 inhibitors on the endothelial glycocalyx, arterial stiffness, myocardial function, and albuminuria. : Overall, 60 patients were randomized to combined dulaglutide and dapagliflozin treatment (n = 30) or DPP-4 inhibitors (DPP-4i, n = 30) (ClinicalTrials.
View Article and Find Full Text PDFCells
December 2024
Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand.
Three-dimensional (3D) tissue culture models provide in vivo-like conditions for studying cell physiology. This study aimed to examine the efficiency of pyramidal microwell geometries in microfluidic devices on spheroid formation, cell growth, viability, and differentiation in mouse embryonic stem cells (mESCs). The static culture using the hanging drop (HD) method served as a control.
View Article and Find Full Text PDFBiomedicines
December 2024
World-Class Research Center «Digital Biodesign and Personalized Healthcare», I.M. Sechenov First Moscow State Medical University (Sechenov University), 8-2 Trubetskaya Street, 119991 Moscow, Russia.
Ischemic heart disease (IHD) impacts the quality of life and is the most frequently reported cause of morbidity and mortality globally. To assess the changes in the exhaled volatile organic compounds (VOCs) in patients with vs. without ischemic heart disease (IHD) confirmed by stress computed tomography myocardial perfusion (CTP) imaging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!