Arthrodesis of the first metatarsophalangeal joint is a commonly accepted technique to treat various afflictions of the hallux. Many techniques have been described to fixate the arthrodesis. However, no superior fixation technique has been identified in regard to nonunion. We performed a retrospective analysis of first metatarsophalangeal joint arthrodeses in our clinic from January 2000 to April 2010, focusing on plate and screw fixation. Our aim was to identify the best fixation construct in regard to fusion rates and radiologic nonunion. We identified 72 arthrodeses performed using 1 oblique (n = 24) or 2 crossed (n = 21) lag screws or a plate (n = 13) or a plate augmented with plantar lag screw fixation (n = 14). Our analysis showed that plate fixation alone results in significantly fewer nonunions than single screw fixation. A comparison of the other fixation types showed no significant differences with regard to nonunion. Although our analysis showed that plate fixation alone is superior to single screw fixation, no definitive conclusion can be drawn owing to methodologic shortcomings. We believe a randomized controlled trial with larger sample sizes is necessary to find the clinically superior fixation technique.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1053/j.jfas.2011.10.044 | DOI Listing |
BMC Musculoskelet Disord
January 2025
Department of Sports Orthopaedics, Klinikum rechts der Isar (Technical University of Munich), Ismaninger Straße 22, 81675, Munich, Germany.
Purpose: This study aims to describe a fixation technique for coronoid fractures using suture buttons, and to biomechanically evaluate this technique in comparison to screw fixation as a time-zero pilot study.
Methods: An O'Driscoll type 2 anteromedial coronoid facet (AMCF) fracture was simulated in 20 fresh-frozen human elbows. The specimens were randomized into two groups and fracture fixation was performed with either a suture button system or a 3.
Injury
December 2024
Golden Jubilee Medical Center, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Background: Severe metaphyseal comminution and sizable bone defect of the distal femur are high risks of fixation failure. To date, no exact magnitude of comminution and bone loss is determined as an indication for augmentation of fixation construct. The present study aimed to investigate the influence of metaphyseal gap width, working length, and screw distribution on the stability of the fixation construct.
View Article and Find Full Text PDFJ Craniofac Surg
October 2024
Department of Plastic and Reconstructive Surgery, Saitama Medical University International Medical Center.
This study aimed to develop a novel reconstruction method for segmental mandibulectomy. In the authors' opinion, reconstruction of the anterior border of the mandibular ramus using a double-arm vascularized fibular flap is important to prevent deformity due to buccal depression and the accumulation of food debris, thereby eliminating masticatory dead space that cannot be filled with prostheses such as implants or dentures. Using conventional reconstruction plates, the reconstructed bone positioned at the anterior border of the mandibular ramus required either fixing with only 1 screw or using 2 plates for stable fixation, making it difficult to position the plates stably.
View Article and Find Full Text PDFClin Spine Surg
December 2024
Department of Orthopaedic Surgery, Keio University School of Medicine, Shinjyuku, Tokyo.
Study Design: Multicenter retrospective cohort study.
Objective: To evaluate the efficacy and safety of using cement-augmented pedicle screw (CAPS) fixation only for the cephalad and caudal vertebral bodies.
Summary Of Background Data: Pedicle screw fixation is less effective in patients with low-quality bone.
Acta Chir Orthop Traumatol Cech
January 2025
Neurochirurgická klinika Fakultní nemocnice Olomouc.
Purpose Of The Study: The annual number of spinal fusion procedures has been increasing and is well documented worldwide. The O-arm is slowly becoming the standard for transpedicular screw insertion. The accuracy and safety of this method have been confirmed by many studies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!