A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Radiopaque drug-eluting beads for transcatheter embolotherapy: experimental study of drug penetration and coverage in swine. | LitMetric

Radiopaque drug-eluting beads for transcatheter embolotherapy: experimental study of drug penetration and coverage in swine.

J Vasc Interv Radiol

Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Cancer Institute, National Institutes of Health, 9000 Rockville Pike, Building 10 Room 1C341 MSC 1182, Bethesda, MD 20892, USA.

Published: February 2012

Purpose: To determine local doxorubicin levels surrounding radiopaque drug-eluting beads (DEBs) in normal swine liver and kidney following transcatheter arterial chemoembolization. The influence of bead size (70-150 μm or 100-300 μm) was compared with regard to tissue penetration and spatial distribution of the bead, as well as eventual drug coverage (ie, amount of tissue exposed to drug).

Materials And Methods: Radiopaque DEBs were synthesized by suspension polymerization followed by incorporation of iodized oil and doxorubicin. Chemoembolization of swine liver and kidney was performed under fluoroscopic guidance. Three-dimensional tissue penetration of "imageable" DEBs was investigated ex vivo with micro-computed tomography (microCT). Drug penetration from the bead surface and drug coverage was evaluated with epifluorescence microscopy, and cellular localization of doxorubicin was evaluated with confocal microscopy. Necrosis was evaluated with hematoxylin and eosin staining.

Results: MicroCT demonstrated that 70-150-μm DEBs were present in more distal arteries and located in a more frequent and homogeneous spatial distribution. Tissue penetration of doxorubicin from the bead appeared similar (∼300 μm) for both DEBs, with a maximum tissue drug concentration at 1 hour coinciding with nuclear localization of doxorubicin. The greater spatial frequency of the 70-150-μm DEBs resulted in approximately twofold improved drug coverage in kidney. Cellular death is predominantly observed around the DEBs beginning at 8 hours, but increased at 24 and 168 hours.

Conclusions: Smaller DEBs penetrated further into targeted tissue (ie, macroscopic) with a higher spatial density, resulting in greater and more uniform drug coverage (ie, microscopic) in swine.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3360470PMC
http://dx.doi.org/10.1016/j.jvir.2011.10.019DOI Listing

Publication Analysis

Top Keywords

drug coverage
16
tissue penetration
12
radiopaque drug-eluting
8
drug-eluting beads
8
drug penetration
8
debs
8
swine liver
8
liver kidney
8
spatial distribution
8
localization doxorubicin
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!