Ischemic preconditioning (IPC) is a well-documented phenomenon. Short episodes of sublethal ischemia provide cardioprotective effects for subsequent longer duration ischemic events. Although the exact mechanism of IPC is not yet known, the chemical basis of IPC seems to involve preservation of ATP or collateral vascularization recruitment. In this case report, we present visual evidence of ischemic preconditioning using Heartscape Technologies 80 Lead ECG device. The 80 Lead ECG is described as a body surface mapping modality, converting its inputted 80 lead ECG data into a 3-Dimensional color coded map. The 80 lead ECG device can detect instantaneous ischemic changes. Different studies have been performed to show different clinical and biochemical aspects of IPC. However data regarding direct visual evidence of this phenomenon is lacking. The secondary objective of this study is to show the ability of 80 lead ECG to identify ST-segment elevation and depression during ischemic events. The utility of 80 Lead ECG body surface mapping is enormous when evaluating ischemic events.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3235991 | PMC |
http://dx.doi.org/10.4137/CCRep.S8455 | DOI Listing |
Cardiol Rev
January 2025
From the Department of Cardiology, Phelps Memorial Hospital/Northwell Health, Sleepy Hollow, NY.
The invention of the string galvanometer by Willem Einthoven in 1901 ushered in a new era of clinical investigation. Previous instruments were capable only of rudimentary measurements that were of limited utility. Advances in physiology and engineering allowed Einthoven to construct a device that was uniquely capable of recording the minute electrical currents of the heart.
View Article and Find Full Text PDFBiotechnol Rep (Amst)
March 2025
Pharmacology Department, National Research Centre, Dokki, Giza, Egypt.
The damaging effects of heavy metal exposure on vital organs like the heart, liver, kidneys, and brain can be lowered by natural compounds' anti-inflammatory and anti-oxidant capacity. In the current investigation, the protective potential of savory()essential oil (EO) against lead acetate-induced multi-organ damage in rats was evaluated. Thirty female Wister Albino rats were divided into the following groups: normal, positive control given lead acetate without concomitant treatment, reference given ethylene-diamine-tetra-acetic acid and groups treated with savory EO (0.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Objective And Rationale: Small studies have shown that the QT interval follows a circadian rhythm. This finding has never been confirmed in a large real-world hospital population and the clinical meaning of disrupted rhythmicity remains unknown.
Methods: In this cohort study, all consecutive adult patients with at least one 12-lead ECG acquired between 1991 and 2021 were considered.
Zhonghua Xin Xue Guan Bing Za Zhi
January 2025
Cardiology Department, Second Affiliated Hospital of Dalian Medical University, Dalian116021, China.
To assess the effectiveness of transcatheter aortic valve replacement (TAVR) on electrocardiographic remodeling in patients with severe aortic stenosis (AS), and identify its influencing factors. A cohort study was conducted on patients with a confirmed diagnosis of severe AS who successfully underwent TAVR at the Second Affiliated Hospital of Dalian Medical University between June 2018 and March 2023. Data, including standard 15-lead electrocardiograms and echocardiograms, were collected before the operation, 1 week after the operation, and 3 months after the operation.
View Article and Find Full Text PDFNPJ Digit Med
January 2025
Department of Medical Informatics, University Medical Center Göttingen, Göttingen, Germany.
Aging affects the 12-lead electrocardiogram (ECG) and correlates with cardiovascular disease (CVD). AI-ECG models estimate aging effects as a novel biomarker but have only been evaluated on single ECGs-without utilizing longitudinal data. We validated an AI-ECG model, originally trained on Brazilian data, using a German cohort with over 20 years of follow-up, demonstrating similar performance (r = 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!