Objectives: To compare self-collected vaginal swab (SCVS) types and first-catch urine (FCU) to diagnose Trichomonas vaginalis using analyte-specific reagents designed to be used in a transcription-mediated amplification assay.
Methods: A total of 241 women (group A) collected a FCU and a SCVS using a dacron swab (APTIMA collection kit). A second group of 289 women (group B) collected two SCVS using one dacron swab and one nylon-flocked swab.
Results: Of 75 young women (street youth) determined to be infected with T vaginalis only seven reported symptoms of vaginal discharge or irritation. Using a cutoff of 50,000 relative light units, the sensitivity and specificity was 97.2% and 97.6%, respectively for dacron SCVS compared with 41.7% and 100% for FCU in group A; 92.3% and 98.8% for dacron SCVS and 92.3% and 99.2% for flocked-nylon SCVS in group B. The assay tested 96 samples in 6 h.
Conclusions: Dacron and nylon-flocked SCVS performed equally well and significantly better than FCU using analyte-specific reagents in the APTIMA transcription-mediated amplification assay. Either swab type could be used for self-collection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/sextrans-2011-050084 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!