This paper presents the parallel hybrid robot, PARASURG 9M, for robotically assisted surgery, a robot which was entirely designed and produced in Romania. It is a versatile robot, being composed of a positioning and orientation module, PARASURG 5M with five degrees of freedom, having the possibility of attaching at its end either a laparoscope or an active surgical instrument for cutting/grasping, PARASIM, with four degrees of freedom. Based on its mathematical modelling, the first low-cost experimental model of the surgical robot has been built. The robot is part of the surgical robotic system, PARAMIS, with three arms, one used as a laparoscope holder, and other two for manipulating active instruments. When it is used as a manipulator of the camera, the user has the possibility to give commands in a large area for the positioning of the laparoscope using different interfaces: joystick, microphone, keyboard & mouse and haptic device. If the active surgical instrument, PARASIM, is attached, the robot commands are given through a haptic device. The main features that make the PARASURG 9M surgical robot suited for minimally invasive surgery are: precision, the elimination of the natural tremor of the surgeon, direct control over a smooth, precise, stable view of the internal surgical field for the surgeon. It also eliminates the need of a second surgeon to be present for the entire procedure (in the case of using the robot as a camera holder). In addition, there is improvement of surgeon dexterity in the case of using the PARASIM active instrument and better ergonomics in using the robot (in the case of the classic laparoscopy, the surgeon must adopt a difficult position for a long period of time, while the robot never gets tired). Having a relatively easy to understand, intuitive commanding system, the surgeons can rapidly adapt to the use of the PARASURG 9M robot in surgical procedures.
Download full-text PDF |
Source |
---|
Knee Surg Sports Traumatol Arthrosc
January 2025
Orthopaedic Robotics Laboratory, Departments of Bioengineering and Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
Purpose: To quantify the effect of increasing the posterior tibial slope (PTS) on knee kinematics and the resultant medial and lateral meniscal forces.
Methods: In this controlled laboratory study, a 6 degrees of freedom (DOF) robotic testing system was used to apply external loading conditions to seven fresh-frozen human cadaveric knees: (1) 200-N axial compressive load, (2) 5-N m internal tibial +10-N m valgus torque and (3) 5-N m external tibial + 10-N m varus torque. Knee kinematics and the resultant medial and lateral meniscal forces were acquired for two PTS states: (1) native PTS and (2) increased PTS.
J Robot Surg
January 2025
The Third Ward of Orthopaedic Department, General Hospital of Ningxia Medical University, 804 Shengli South Street, Hui Autonomous Region, Yinchuan, Ningxia, 750004, People's Republic of China.
The purpose of this study is to assess the safety and effectiveness of TiRobot-assisted treatment for femoral neck fractures, in comparison to traditional freehand treatment methods. Throughout the research process, we conducted an extensive literature search across numerous databases, including PubMed, EMBASE, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), CQVIP, and Wanfang. Based on the literature screening criteria, we selected six studies, encompassing 358 cases of femoral neck fracture patients, for this meta-analysis.
View Article and Find Full Text PDFWorld J Urol
January 2025
Department of Urology, Urooncology, Robot-assisted and Focal Therapy, University Hospital Magdeburg, Otto-von Guericke University Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Germany.
Background And Objectives: Radical prostatectomy is a standard treatment for prostate cancer, yet about 30% of patients experience rising biochemical markers within a decade post-surgery. Pelvic lymph node sampling during prostatectomy assesses potential lymph node metastases, but standard histological assessments, which typically examine only 2-3 tissue sections, often miss occult metastases. This study assesses the effectiveness of qPCR in detecting PSA coding KLK3 mRNA for identifying lymph node metastases post-prostatectomy and explores the correlation between PSA-mRNA and biochemical recurrence.
View Article and Find Full Text PDFAnn Surg Oncol
January 2025
AdventHealth Tampa, Digestive Health Institute, Tampa, Florida, USA.
J Robot Surg
January 2025
Department of Pediatric Anesthesia and Intensive Care, Necker-Enfants Malades University Hospital, AP-HP Centre, Université Paris Cité, 149, Rue de Sèvres 75015, Paris, France.
Retroperitoneal robotic-assisted laparoscopic pyeloplasty (R-RALP) is the commonest urologic procedure performed in children, entailing retroperitoneal CO2 insufflation and lateral decubitus, whose effects on cardiopulmonary variables are poorly known. We, therefore, studied hemodynamic and respiratory changes due to CO2 insufflation and lateral decubitus in children undergoing R-RALP and their effects on regional tissue oxygenation. Between 1/2021 and 7/2024, children affected by ureteropelvic joint obstruction (UPJO) underwent a pyeloplasty by R-RALP at Necker Enfants Malades Hospital (Paris, France), using a standardized surgical technique and a lung-protecting anesthetic protocol aimed to prevent hypercarbia.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!