During percutaneous mitral balloon valvuloplasty, the Inoue method leaves patients with an iatrogenic atrial septal defect. In this study, we evaluated the factors affecting the development of iatrogenic atrial septal defect and searched for the possible influence of this defect on long-term outcomes.We reviewed the medical records of 267 patients who had undergone successful percutaneous mitral balloon valvuloplasty for symptomatic moderate or severe mitral stenosis from January 2000 through March 2004. Sixty-three of the 267 patients were enrolled in a face-to-face follow-up study. We noted their clinical and demographic characteristics. All included patients were asked for the endpoints of repeat percutaneous mitral balloon valvuloplasty or mitral valve surgery, cerebrovascular accident or transient ischemic attack, and the need of intervention for the iatrogenic atrial septal defect. They underwent standard 2-dimensional and Doppler echocardiographic examination. The presence of iatrogenic atrial septal defect was evaluated via the color-Doppler technique in the subcostal view and via contrast echocardiography.Patients were subclassified in accordance with the presence (n = 15) or absence (n = 48) of echocardiographically proven persistent iatrogenic atrial septal defect. When we compared the 2 groups, there were no significant differences in baseline demographic characteristics or in pre- and postprocedural echocardiographic data.We conclude that the presence of persistent iatrogenic atrial septal defects might not be predicted from echocardiographic or demographic data in patients undergoing percutaneous mitral balloon valvuloplasty. Fortunately, these defects are small in size and low in shunt ratio. They appear not to be associated with serious long-term outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3231525PMC

Publication Analysis

Top Keywords

iatrogenic atrial
28
atrial septal
28
septal defect
24
percutaneous mitral
20
mitral balloon
20
balloon valvuloplasty
20
267 patients
8
demographic characteristics
8
persistent iatrogenic
8
iatrogenic
7

Similar Publications

Evaluation of Non-Invasive Hemoglobin Monitoring in Perioperative Patients: A Retrospective Study of the Rad-67 (Masimo).

Diagnostics (Basel)

January 2025

Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Oberdürrbacher Str. 6, 97080 Würzburg, Germany.

: Hemoglobin (Hb) is a crucial parameter in perioperative care due to its essential role for oxygen transport and tissue oxygenation. Accurate Hb monitoring allows for timely interventions to address perioperative anemia and, thus, prevent morbidity and mortality. Traditional Hb measurements rely on invasive blood sampling, which significantly contributes to iatrogenic anemia and poses discomfort and increased infection risks.

View Article and Find Full Text PDF

Postablation Arrhythmogenic Channels Predict Atrial Fibrillation Recurrence: Iatrogenic Substrate Revisited.

JACC Clin Electrophysiol

January 2025

Department of Cardiology, Hospital Clínic Cardiovascular Institute (ICCV), Universitat de Barcelona, Barcelona, Catalonia, Spain; Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Catalonia, Spain. Electronic address:

View Article and Find Full Text PDF

Background: Intracardiac echocardiography (ICE) appears to be a potential alternative for percutaneous left atrial appendage occlusion (LAAO) to transesophageal echocardiography (TEE). Thus, a meta-analysis was performed comparing ICE vs. TEE for LAAO guidance.

View Article and Find Full Text PDF

Iatrogenic diversion of inferior vena cava to the left atrium presented as persistent hypoxemia: Case series.

Medicine (Baltimore)

January 2025

Department of Center for Pulmonary Vascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Rationale: The transcatheter closure and atrioseptopexy are the main treatment methods for atrial septal defect (ASD). However, persistent hypoxemia due to iatrogenic diversion of inferior vena cava (IVC) to the left atrium (LA) is reported as a rare complication after ASD closure. Contrast echocardiology is a reliable and powerful tool to detect iatrogenic diversion and identify the etiology accurately.

View Article and Find Full Text PDF

Using transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) to investigate the occurrence and related causes of iatrogenic atrial septal defect (iASD) after catheter ablation combined with left atrial appendage closure (LAAC) for atrial fibrillation (AF) and its impact on the right heart system. We retrospectively analyzed 330 patients that underwent combined procedure of catheter ablation for AF and LAAC at General Hospital of Northern Theater Command from January 2018 to March 2022. These patients were divided into iASD group and non-iASD group according to whether there was persistent iASD shown on TEE at 3 months after procedure.

View Article and Find Full Text PDF