BACKGROUND: Various factors, such as the optimal number of passes, aspiration pressure, and the use of 19-gauge and Trucut biopsy needles, have been studied to improve the diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). We retrospectively compared the diagnostic accuracy of EUS-FNA between 25- and 22-gauge needles, which have been widely used recently. SUBJECTS AND METHODS: The study group comprised 47 consecutive patients who underwent EUS-FNA with both 22- and 25-gauge needles from October 2007 through March 2010. Their underlying diseases were pancreatic cancer in 24 patients, submucosal tumors in 11, other pancreatic tumors in 4, chronic pancreatitis in 4, enlarged lymph nodes in 3, and gall bladder cancer in 1. Tissue specimens, which were pushed out of the puncture needle, were placed into physiological saline solution. Gray-whitish, worm-like specimens were used for histologic diagnosis. The remaining specimen was centrifuged, and the sediment was plated on slides and examined by a cytopathologist to obtain the cytologic diagnosis. RESULTS: A total of 75 punctures (mean, 1.6) were performed with 25-gauge needles, and 69 punctures (mean, 1.4) were performed with 22-gauge needles. The overall tissue-sampling rate for cytology was 100% (47/47), which was significantly (p=0.01) superior to 83% (39/47) for histology. The overall diagnostic accuracy on the cytologic and histologic examinations was 79% (37/47) and 85% (33/39) (p=0.48). According to needle type, the tissue-sampling rate for cytology and histology on each puncture was 97% (73/75) and 56% (42/75) with 25-guage needles, and was 97% (67/69) and 58% (40/69) with 22-guage needles, the accuracy of cytologic diagnosis on each puncture was 73% (53/73) with 25-gauge needles and 66% (44/67) with 22-gauge needles (p=0.37); the accuracy of histologic diagnosis on each puncture was 60% (25/42) and 75% (30/40) (p=0.14), respectively. No patient had complications. CONCLUSIONS: The tissue-sampling rate and diagnostic accuracy did not differ significantly between 22- and 25-gauge needles in patients with pancreatic or gastrointestinal diseases who underwent EUS-FNA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3234693PMC
http://dx.doi.org/10.4161/jig.1.3.18508DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
20
25-gauge needles
20
22- 25-gauge
12
22-gauge needles
12
tissue-sampling rate
12
needles
11
accuracy endoscopic
8
endoscopic ultrasound-guided
8
ultrasound-guided fine-needle
8
fine-needle aspiration
8

Similar Publications

Simultaneous and Ultraspecific Optical Detection of Multiple miRNAs Using a Liquid Flow-Based Microfluidic Assay.

ACS Appl Mater Interfaces

January 2025

Department of Chemistry, Yeungnam University, 280 Daehak-ro, Gyeongsan-si, Gyeongsangbuk-do 38541, Republic of Korea.

Recent studies have reported that the cause and progression of many diseases are closely related to complex and diverse gene regulation involving multiple microRNAs (miRNAs). However, most existing methods for miRNA detection typically deal with one sample at a time, which limits the achievement of high diagnostic accuracy for diseases associated with multiple gene dysregulations. Herein, we develop a liquid flow-based microfluidic optical assay for the simple and reliable detection of two different target miRNAs simultaneously at room temperature without any enzymatic reactions.

View Article and Find Full Text PDF

ECG Patterns of Occlusion Myocardial Infarction: A Narrative Review.

Ann Emerg Med

January 2025

Department of Emergency Medicine, University of Minnesota, Minneapolis, MN; Department of Emergency Medicine, Hennepin Healthcare, Minneapolis, MN.

The traditional management of acute coronary syndrome has relied on the identification of ST-segment elevation myocardial infarction (STEMI) as a proxy of acute coronary occlusion. This conflation of STEMI with acute coronary occlusion has historically overshadowed non-ST-segment elevation myocardial infarction (NSTEMI), despite evidence suggesting 25% to 34% of NSTEMI cases may also include acute coronary occlusion. Current limitations in the STEMI/NSTEMI binary framework underscore the need for a revised approach to chest pain and acute coronary syndrome management.

View Article and Find Full Text PDF

Ultrasound-guided intercostal nerve injection in rabbit cadavers: Technique description and comparison with blind approach.

Vet Anaesth Analg

December 2024

Department of Comparative Diagnostic, and Population Medicine, College of Veterinary Medicine, University of Florida, Gainesville, FL, USA. Electronic address:

Objective: To develop an ultrasound-guided technique for intercostal nerve blocks in rabbit cadavers and to compare the success rate and potential complications of this technique to blind injection.

Study Design: Prospective, randomized, blinded, descriptive experimental cadaveric study.

Animals: A group of nine adult domestic rabbit cadavers (body mass 1.

View Article and Find Full Text PDF

To evaluate the clinical value of multi-slice spiral CT in preoperative TNN staging and postoperative recurrence and metastasis of colon carcinoma, and to provide evidence for the reliability of CT in the diagnosis of colon carcinoma METHODS: 89 patients with colon carcinoma diagnosed pathologically in our hospital from July 2020 to April 2023 were selected retrospectively. The preoperative TNN staging and postoperative recurrence and metastasis were monitored by 64 row 128 layer spiral CT. The diagnostic coincidence rate, TNM staging coincidence rate and postoperative recurrent TNM staging accuracy were evaluated according to the pathological diagnosis RESULTS: The diagnostic coincidence rate of multi-slice spiral CT was 97.

View Article and Find Full Text PDF

Evaluation of a next generation sequencing assay for Hepatitis B antiviral drug resistance on the oxford nanopore system.

J Clin Virol

January 2025

Division of Medical Microbiology and Virology, St. Paul's Hospital, Providence Health Care, Vancouver, British Columbia, Canada; Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada. Electronic address:

Background: Next-generation sequencing (NGS) for Hepatitis B virus (HBV) antiviral resistance (AVR) testing is a highly sensitive diagnostic method, able to detect low-level mutant subpopulations. Our clinical virology laboratory previously transitioned from DNA hybridization (INNO-LiPA) to NGS, initially with the GS Junior System and subsequently the MiSeq. The Oxford Nanopore Technology (ONT) sequencing system was evaluated for HBV resistance testing, with regards to sequencing accuracy and turn-around time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!