Luminescence
Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, and Department of Chemistry, Fuzhou University, Fuzhou, Fujian, 350002, China.
Published: April 2012
The electrochemiluminescence (ECL) behavior of luminol on a nafion-nano-TiO(2) modified glassy carbon electrode (nafion-nano-TiO(2)--GCE) was studied. Two ECL peaks (ECL-1 and ECL-2) were found during cathodic potential scanning. ECL-1 at ca -0.4 V (vs Ag--AgCl reference electrode) came from the reaction between luminol and active oxygen anion produced at the GCE surface directly, while ECL-2 at ca -0.9 V (vs Ag--AgCl reference electrode) came from the reaction between luminol and the active oxygen anion catalyzed by TiO(2.) The possible mechanism for the generation of both ECL peaks has been proposed. The reproducibility of the ECL intensities on nafion-nano-TiO(2)--GCE at ECL-1 and ECL-2 was good, with relative standard deviations (n = 10) of 4.3 and 1.3%, respectively. The ECL-2 generated at the nafion-nano-TiO(2)--GCE surface was further developed to detect the dissolved oxygen, and a detection limit of 0.02 mg/L was achieved. The proposed method was applied to detect dissolved oxygen in water with satisfactory result.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/bio.1265 | DOI Listing |
Anal Chim Acta
February 2025
Key Laboratory of Luminescence Analysis and Molecular Sensing (Ministry of Education), College of Pharmaceutical Sciences, Southwest University, Chongqing, 400715, China. Electronic address:
Background: Drug enantiomers often display distinguishable or even opposite pharmacological and toxicologic activities. Therefore it is of great necessity to discriminate enantiomers for guaranteeing safetyness and effectiveness of chiral drugs. Facile chiral discrimination has long been a noticeable challenge because of the minimal differences in physicochemical properties of enantiomers.
View Article and Find Full Text PDFAnal Chem
January 2025
School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510632, China.
Luminol is a well-known electrochemiluminescence (ECL) fluorophore that is applied in various sensing fields as an ECL reporter. Regulating the signal off/on transition of an ECL fluorophore offers great opportunities for sensors' design; however, such attempts on luminol are extremely scarce as it was regarded to lack promising modification sites. In this study, we developed four luminol derivatives with modification at the amine site and the enol site and systematically explored possible caging strategies to regulate ECL emission.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
March 2025
College of Chemistry, Chemical Engineering and Environment, Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, Micro-Nano Organic Optical Materials Laboratory, Minnan Normal University, Zhangzhou 363000, China.
The type of coordinated N atoms in the metal-N coordination structure is of paramount importance to the catalytic property of N-modified carbon-based single-atom catalysts (SACs). Extended X-ray absorption fine structure (EXAFS) spectroscopy is a powerful tool for analyzing the coordination environments of SACs. Despite its efficacy, the limited availability of synchrotron light sources and the complexity of data analysis have constrained its broader application in identifying metal-N coordination types within SACs.
View Article and Find Full Text PDFMikrochim Acta
October 2024
State Key Laboratory of Food Nutrition and Safety, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin, 300457, P. R. China.
A novel glow-type chemiluminescence (CL)-based nanosensing system was developed for sensitive and rapid point-of-care testing (POCT) of HO in food. CuSe nanoparticles (CuSe) have excellent peroxidase-like activity. After being modified with thiols of 4-mercaptophenylboronic acid (MBA) (CuSe@MBA), luminol can be catalyzed to produce long-lasting CL in the presence of HO.
View Article and Find Full Text PDFAnal Chem
June 2024
School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001, China.
In traditional luminol electrochemiluminescence (ECL) systems, hydrogen peroxide (HO) and dissolved oxygen (DO) are the commonly used coreactants to generate reactive oxygen species (ROS) for ECL emission. However, the self-decomposition of hydrogen peroxide and the limited solubility and content of oxygen in solution undoubtedly restrict the luminescence efficiency and stability of the luminol ECL system. Inspired by the ROS-mediated ECL mechanism, we pioneered hydroxide ion as an advanced luminol ECL coreactant using nickel-doped and carbon nanotube-modified tungsten oxide (Ni-WO-CNT) as the coreactant accelerator.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!
© LitMetric 2025. All rights reserved.